![AR 10010475 Operating And Service Manual Download Page 40](http://html.mh-extra.com/html/ar/10010475/10010475_operating-and-service-manual_2962269040.webp)
40T18G26A
Table 3-5. Catalog of Fault Codes
(The RDFLT command causes the TWTA to return a string in the form flt=[
code
], where [
code
] is an ASCII
number whose meaning is given below)
Fault Code
Meaning
0 No
fault
7 System
Fault
8
Fil not ready
9 Low
Line
10
Cathode overvoltage
11 Body
overcurrent
12 Cathode
undervoltage
15 Collector
undervoltage
16 Inverter
fault
17
Internal interlock open
18 Tube
arc
19 TWT
(hardware)
overtemperature
20
Cabinet (hardware) overtemperature
22 External
inhibit
23
Over reverse power
30
Grid or anode overvoltage
49 TWT
(software)
overtemperature
50
Cabinet (software) overtemperature
20
Rev C
Summary of Contents for 10010475
Page 2: ......
Page 4: ......
Page 14: ......
Page 16: ......
Page 24: ......
Page 48: ...40T18G26A 28 Rev C ...
Page 52: ...40T18G26A 32 Rev C ...
Page 68: ...40T18G26A 48 Rev C ...
Page 70: ......