AR 10008384 Operating And Service Manual Download Page 25

 

 

WARRANTIES:  LIMITATION OF LIABILITY

 

 

Seller warrants (i) that seller has title to the goods sold and (ii) that Amplifiers (all parts excluding traveling wave 

and vacuum tubes), Antennas, field monitors, field probes, field analyzers, field analyzer processor units, system 

controllers, system interlock, power meters, leak detectors, RF conducted probes, RF conducted clamps, Multi-

tone, EMI receiver systems, RF down converters, RF conducted immunity systems, conducted immunity 

accessories, radiated immunity test systems,  safety meters, safety sensor heads, tripods, directional couplers, 

waveguide adapters, termination loads, load attenuators, impedance stabilization networks, and coaxial cables will 

be free from defects in material and workmanship for a period of three (3) years from date of shipment shown on 

AR RF/Microwave Instrumentation invoice.

 

All modules, used in the amplifiers for the 1-6 GHz, 4-18 GHz, 6-18 GHz, all HPM products, and other 

applications, are hermetically-sealed. This sealing process protects the internal hybrid circuitry from humidity that 

could compromise the long term reliability of the product.  These modules are not field-repairable and should 

never

 be opened outside of AR’s Microelectronics Lab.  The modules in these product lines have a security label 

on two sides of the modules between the housing and lid/cover. If the security label is removed and or cut, the 

warranty of the module will be voided. 

Vacuum tubes in the ‘L’ series amplifiers, traveling-wave tubes in TWT amplifiers, and power heads will be free 

from defects in material and workmanship for a period of one (1) year.  

Contact AR RF/Microwave Instrumentation for warranty information regarding items not listed.   

Seller’s sole responsibility in fulfilling these warranties shall be to repair or replace any goods which do not 

conform to the foregoing warranties or, at seller’s option, to give buyer credit for defective goods.  The warranty 

is valid only when used in the country specified at time of order.  Warranty service must be obtained from the 

repair facility designated at that time.  If warranty service is not available in the country where the equipment is to 

be used, it must be returned to AR RF/Microwave Instrumentation.  Warranty service will be provided only for 

defective goods which are returned within the warranty period, freight costs prepaid to AR RF/Microwave 

Instrumentation or its designated repair facility. 

There are no other warranties, express or implied, including any warranty of merchantability or fitness.  Seller 

shall not be responsible for any incidental or consequential damages arising from any breach of warranty. 

No person other than an officer of Amplifier Research Corporation, has any authority to bind seller to any 

affirmation, representation or warranty except as specifically included in the preceding terms and conditions. 

 

 

Rev 1216 

 

 

Summary of Contents for 10008384

Page 1: ...Operating and Service Manual ATH18G27 1 Model 10008384 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Page 2: ......

Page 3: ...ction of the use of certain hazardous substances in electrical and electronic equipment recast RECYCLING WEEE DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste...

Page 4: ......

Page 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Page 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Page 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Page 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Page 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Page 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Page 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Page 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Page 13: ...1 2 Specifications 1 1 3 Performance Data 1 1 4 Installation 1 1 4 1 Connections 2 1 4 2 Power Amplifier Selection 2 1 4 3 General Caution Notes 2 2 TYPICAL CURVES 5 3 OUTLINE DRAWING 7 4 POLARIZATIO...

Page 14: ......

Page 15: ...uding Voltage Standing Wave Ratio VSWR for the Model ATH18G27 1 1 3 PERFORMANCE DATA Typical Gain versus Frequency and Calculated Field Strength 1m and 3m versus Frequency data for the Model ATH18G27...

Page 16: ...18G26 Model 40T18G26 and other T Series MW Traveling Wave Tube TWT amplifiers available from AR RF Microwave Instrumentation 1 4 3 General Caution Notes CAUTION The Model ATH18G27 1 is capable of gene...

Page 17: ...tough enough for the extra demands of outdoor use and easily mounts on a rigid waveguide by the waveguide flange Part of a family of microwave frequency antennas the Model ATH18G27 1 provides the 18 0...

Page 18: ...0 22 24 26 28 FREQUENCY GHz H Plane Beamwidth E Plane Beamwidth Gain H E Field strengths have been measured in free space conditions Individual shielded rooms amplifiers and test system conditions wil...

Page 19: ...m and 3m versus Frequency for the Model ATH18G27 1 Microwave Horn Antenna ATH18G27 1 GAIN 3dB BEAMWIDTH VS FREQ 8 5 9 9 5 1 0 1 0 5 1 1 1 1 5 1 2 GAIN dBi 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 BEAM WIDTH DE...

Page 20: ...ATH18G27 1 6 Rev A...

Page 21: ...Rev A 7 3 OUTLINE DRAWING An outline drawing Drawing Number 10009383 of the Model ATH18G27 1 Microwave Horn Antenna is included in this section Drawing 10008383 Rev...

Page 22: ...ATH18G27 1 8 Rev A...

Page 23: ...Rev A 9 4 POLARIZATION OF HORN ANTENNAS...

Page 24: ...ATH18G27 1 10 Rev A...

Page 25: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Page 26: ......

Reviews: