AR 10006310 Operating And Service Manual Download Page 1

 

 

 

 

 

 

 

Operating and 

Service Manual 

 

 

 

 

 

ATH7G18 
Model 
 
10006310 
Part Number 
 
 
Serial Number 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us

 

Summary of Contents for 10006310

Page 1: ...Operating and Service Manual ATH7G18 Model 10006310 Part Number Serial Number 160 School House Road Souderton PA 18964 215 723 8181 Fax 866 859 0582 www arworld us...

Page 2: ...2...

Page 3: ...ction of the use of certain hazardous substances in electrical and electronic equipment recast RECYCLING WEEE DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste...

Page 4: ...4...

Page 5: ...clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Do not restrict airflow into the equipment by blocking any vents or air intakes Restricting airflow...

Page 6: ...a assembly may be heavy requiring two persons to lift Use caution when installing or removing unit Follow all equipment setup and lifting instructions specified in this document Ensure connectors are...

Page 7: ...von 10 2 cm 4 in auf allen bel fteten Seiten des Ger ts ein um eine ausreichende Luftzirkulation zu gew hrleisten Beintr chtigen Sie den Luftstrom des Ger ts nicht indem Sie L ftungs ffnungen oder de...

Page 8: ...allen in diesem Dokument angegebenen Anweisungen zur Anbringung Stellen Sie sicher dass alle Anschl sse f r den beabsichtigten Betrieb geeignet sind Informationen zu den Anschl ssen erhalten Sie im Be...

Page 9: ...tilation Ne limitez pas le flux d air allant dans l quipement en bloquant tout vent ou entr e d air La restriction du flux d air peut endommager l quipement causer des coupures intermittentes ou des d...

Page 10: ...dent lorsque vous installez ou retirez l unit Respectez toutes les instructions concernant l installation et le levage de l quipement indiqu es dans ce document Assurez vous que les connecteurs sont a...

Page 11: ...is voor goede ventilatie mogelijk te maken Belemmer de luchtstroom in het apparaat niet door ventilatieopeningen of luchtinlaten te blokkeren Het belemmeren van de luchtstroom kan leiden tot schade a...

Page 12: ...nstellen en optillen van de apparatuur die in dit document worden vermeld Zorg ervoor dat de connectoren geschikt zijn voor de beoogde werking De connectoren worden gespecificeerd in de gebruikershand...

Page 13: ...Pattern 8 0GHz 8 2 5 E Plane Radiation Pattern 9 0GHz 9 2 6 H Plane Radiation Pattern 9 0GHz 10 2 7 E Plane Radiation Pattern 10 0GHz 11 2 8 H Plane Radiation Pattern 10 0GHz 12 2 9 E Plane Radiation...

Page 14: ......

Page 15: ...ifications 1 3 PERFORMANCE DATA Typical Model ATH7G18 Antenna Gain Curve is included 1 4 INSTALLATION Before proceeding thoroughly inspect the antenna for any signs of physical damage which may have i...

Page 16: ...us to human life as well as causing serious RF burns Never walk in front of the horn when it is radiating Operation of this antenna and associated equipment should only be performed by the personnel t...

Page 17: ...y often used test specifications The ATH7G18 can also be custom calibrated to the user s requirement for use in RF emission testing The calibrated model is designated by adding a CC suffix to the desi...

Page 18: ...7 5 8 0 8 5 9 0 9 5 1 0 0 1 0 5 1 1 0 1 1 5 1 2 0 1 2 5 1 3 0 1 3 5 1 4 0 1 4 5 1 5 0 1 5 5 1 6 0 1 6 5 1 7 0 1 7 5 1 8 0 1 8 5 Frequency GHz Gain dBi without Gain Enhancer With Gain Enhancer ATH7G18...

Page 19: ...1 WATT 2 WATT 5 WATT 10 WATT 20 WATT 50 WATT 100 WATT 200 WATT 500 WATT 1000 WATT 2000 WATT 100 1000 10000 ATH7G18 Without Gain Enhancer 3 meters 1 00 10 00 100 00 7 0 7 5 8 0 8 5 9 0 9 5 1 0 0 1 0 5...

Page 20: ...5 1 4 0 1 4 5 1 5 0 1 5 5 1 6 0 1 6 5 1 7 0 1 7 5 1 8 0 1 8 5 Frequency GHz Field Strength V m 100 1000 10000 1 WATT 2 WATT 5 WATT 10 WATT 20 WATT 50 WATT 100 WATT 200 WATT 500 WATT 1000 WATT 2000 WA...

Page 21: ...Rev C 5 2 Typical Curves 2 1 GAIN VSWR AND 3DB BEAMWIDTH...

Page 22: ...Model ATH7G18 6 Rev C 2 2 GAIN VS FREQUENCY...

Page 23: ...Model ATH7G18 Rev B 7 2 3 E PLANE RADIATION PATTERN 8 0GHZ...

Page 24: ...Model ATH7G18 8 Rev C 2 4 H PLANE RADIATION PATTERN 8 0GHZ...

Page 25: ...Model ATH7G18 Rev B 9 2 5 E PLANE RADIATION PATTERN 9 0GHZ...

Page 26: ...Model ATH7G18 10 Rev C 2 6 H PLANE RADIATION PATTERN 9 0GHZ...

Page 27: ...Model ATH7G18 Rev B 11 2 7 E PLANE RADIATION PATTERN 10 0GHZ...

Page 28: ...Model ATH7G18 12 Rev C 2 8 H PLANE RADIATION PATTERN 10 0GHZ...

Page 29: ...Model ATH7G18 Rev B 13 2 9 E PLANE RADIATION PATTERN 12 0GHZ...

Page 30: ...Model ATH7G18 14 Rev C 2 10 H PLANE RADIATION PATTERN 12 0GHZ...

Page 31: ...Model ATH7G18 Rev B 15 2 11 E PLANE RADIATION PATTERN 14 0GHZ...

Page 32: ...Model ATH7G18 16 Rev C 2 12 H PLANE RADIATION PATTERN 14 0GHZ...

Page 33: ...Model ATH7G18 Rev B 17 2 13 E PLANE RADIATION PATTERN 16 0GHZ...

Page 34: ...Model ATH7G18 18 Rev C 2 14 H PLANE RADIATION PATTERN 16 0GHZ...

Page 35: ...Model ATH7G18 Rev B 19 2 15 E PLANE RADIATION PATTERN 18 0GHZ...

Page 36: ...Model ATH7G18 20 Rev C 2 16 H PLANE RADIATION PATTERN 18 0GHZ...

Page 37: ...Rev C 21 3 OUTLINE DRAWING Drawing 10006309 Rev D...

Page 38: ...Model ATH7G18 22 Rev C...

Page 39: ...Rev C 23 4 POLARIZATION OF HORN ANTENNAS...

Page 40: ...Model ATH7G18 24 Rev C...

Page 41: ...cover If the security label is removed and or cut the warranty of the module will be voided Vacuum tubes in the L series amplifiers traveling wave tubes in TWT amplifiers and power heads will be free...

Page 42: ......

Reviews: