![AR 10006031 Operating And Service Manual Download Page 28](http://html1.mh-extra.com/html/ar/10006031/10006031_operating-and-service-manual_2962262028.webp)
Model 200T4G8
3.7
Emergency Bypass Operation
For reference, see schematic 10-24369-000 in section 5.2.
The TWTA is provided with a means of operating the amplifier manually in the event that there is a failure of
the control module and it is imperative that the amplifier remains on line.
CAUTION:
Emergency bypass operation disables external interlock and certain
protective and diagnostic features. For this reason, the emergency bypass
mode of operation should be used only when the control unit fails and
when it is essential to remain on line.
To access the manual controls, remove the two 4-40 screws securing the Emergency switch cover plate on the
front panel. Emergency bypass mode is selected by pushing the left-hand switch (S1) to the left. The center
switch (S2) toggles between high voltage on (left) and high voltage off (right). The right-hand switch (S3)
selects between beam on (left) and beam off (right). There is a manual control for the gain adjustment as well.
This is a flat, square single-turn pot (R1).
CAUTION:
Do not adjust 20-turn pot R11; its function is to set the foldback VSWR
level, and it is calibrated at the factory.
3.8 REMOTE IEEE-488 OPERATION
The TWTA is provided with an IEEE-488 interface that permits remote emulation of OPERATE,
STANDBY, and RESET push-buttons as well as access to parameter measurements, system faults, and
control unit status. The following tables summarize the commands and the return codes.
Table 3-3. Catalog of IEEE-488 Commands
Command Function
Units
Response
format
RDSTAT
Returns status code of processing of previous command (see Table
3-4)
STATUS=[
]
RDFLT
Returns system fault code (see Table 3-5)
flt=[ ]
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK
Returns cathode voltage
KV
Ek=[ ]
RDEB
Returns collector voltage
KV
Eb=[ ]
RDEG (or RDEA)
Returns grid (or anode) voltage
V
Eg=[ ] (Ea=[])
RDEF
Returns heater voltage
V
Ef=[ ]
RDIF
Returns heater current
A
If=[ ]
RDIW
Returns helix current
mA
Iw=[ ]
18
Rev. F
Summary of Contents for 10006031
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ...Model 200T4G8 2 Rev F...
Page 36: ...Model 200T4G8 26 Rev F...
Page 40: ...Model 200T4G8 30 Rev F...
Page 44: ...Model 200T4G8 34 Rev F...
Page 46: ...Model 200T4G8 36 Rev F...
Page 60: ...Model 200T4G8 50 Rev F...
Page 62: ......