![AR Blue Clean AR383SS Instruction Manual Download Page 13](http://html1.mh-extra.com/html/ar-blue-clean/ar383ss/ar383ss_instruction-manual_2962415013.webp)
13
OFF/0
ON/I
OFF/0
ON/I
o
Perating
i
nStrUctionS
*!Turn on the water supply at the faucet.!*
(Fig. 18)
Powering Up
• Make sure the “ON/OFF” switch is in the “OFF” position. The power switch has international
symbols for ‘on’ and ‘off’: On (|) Off (O),
(Fig. 19)
.
• Unwind the power cord completely and plug the GFCI into a grounded 120 volt outlet. Press the
‘
reset
’ button on the GFCI box
(Fig. 20)
. The indicator window should show a red color. This must
be done each time the unit is plugged in.
• Release the safety lock button on the spray gun by pressing the safety lock in the back under
the handle
(Fig. 21)
. While pointing the spray gun in a safe direction, squeeze the trigger on the
spray gun until there is a steady stream of water, letting the water and air out of the hose. Press
the button in front to lock the trigger.
• Turn the power switch to the ‘ON’ (|) position. The unit will turn on for 1 - 2 seconds and shut off,
this is a normal function of the (TSS) auto start feature. Squeeze the spray gun trigger to begin
pressure washing.
• Squeezing rapidly will cause the (TSS) feature to miss an on/off cycle that may prevent from
turning on while squeezing trigger after rapid squeezing. Use slow deliberate trigger pulls to
avoid such symptoms.
Fig. 19
Fig. 18
Fig. 20
Fig. 21
Trigger Lock
Trigger Unlock