5

POLISHING CARTRIDGE INSTALLATION

The Polishing Cartridge contains carbon that will offer a finished 

taste to the drinking water. This is the last cartridge to filter the 

water before the water flows from the newly-installed Chrome 

Faucet.

WATER STORAGE TANK INSTALLATION

The Water Storage Tank included with your kit is more than meets 

the eye. Inside the tank is a bladder made of a butyl rubber 

designed for drinking water applications. Water will never touch 

the actual metal tank as it enters and leaves the tank. To learn more 

about the Tank, refer to the section on Unit Maintenance.

Step 2 – Choose a location that 

is easy to access for when the 

cartridge needs to be replaced 

and secure the two clips to the 

cabinet wall using the screws 

provided.

Step 1 – Apply three rounds of 

the plumbers tape to the nipple 

on the top end of the Water 

Storage Tank.

Step 2 – Thread the Pressure 

Tank Valve onto the ¼” nipple 

on the end of the Water Storage 

Tank and hand tighten.

Step 1 – Apply three rounds 

of the plumbers tape to the 

¼” MPT x ¼” Press Fit Adapters 

and then thread the Adapters 

into the ends of the Polishing 

Cartridge. Use an Adjustable 

Wrench to tighten. Use caution 

not to over-tighten the plastic.

1

3

4

5

2

Correct

Incorrect

HOW TO USE THE BUDDIE FIT™ PRESS FITTINGS

To make easy ¼”  tubing connections with the included Buddie Fit™

press fittings, follow these simple steps:

Collet

Tubing

Collet Flange

O-ring

Blue

Clip

Blue Clip

Tubing

Push 2x

Tubing

Pull

NOTE:

 To remove tubing, remove the blue clip.

Press in and hold the collet while pulling out tubing

NOTE:

 We recommend cutting the tubing with

a straight-edged razor blade or a tool designed
to cut flexible water line.

1.  Remove the blue clip

 

from the press fitting.

2.  Make sure the end

 

of the tubing is cut

 

evenly and not at

 

an angle.

3.  Push the tubing into

 

the fitting. You will hit

 

the first stop.

 

The tubing is still not

 

secured properly.

 

Push the tubing a

 

second time and you

 

will feel the tubing insert

 

completely into the

 

press fitting. 

4.  Pull back on the tubing

 

to ensure it is secure.

5.  Insert the locking

 

blue clip back onto

 

the end of the

 

press fitting.

Summary of Contents for 540491

Page 1: ...ly before proceeding with installation Your failure to follow any attached instructions and operating parameters may lead to the product s failure Contents Model 540491 1 Under Sink Water Line Adapter Valve Female x Male x Press Fit 1 Polishing Carbon Cartridge 1 Pressure Sensitive Solenoid 2 Carbon Cartridge Clips 1 Chrome Faucet 2 MPT x Press Fit Adapters 1 In line Check Valve 1 Set Mounting Scr...

Page 2: ...rs PLUMBING DIAGRAM Regardless of your individual RO Filtration Unit looks the water path will be the same for installation It is important to follow the path correctly to ensure proper operation Faucet Carbon Polishing Cartridge Pressure Tank Tank Valve Saddle Valve Sink Drain Waste Filtered Sediment Carbon Membrane Check Valve Sink Valve Pressure Sensitive Solenoid 3 Stage Twist In Reverse Osmos...

Page 3: ...disposal to insure proper drainage Locate where the Drain Saddle will be mounted and mark with a piece of masking tape and pencil Step 4 Use a drill bit to make a hole in the drain pipe where you marked it on the masking tape Remove the masking tape and clear any plastic burs shavings from around the new hole in the drain pipe Step 5 Align the Drain Saddle with the new hole in the drain pipe using...

Page 4: ...1 2 drill bit Using the different size bits to enlarge the hole will make it easier to achieve the final diameter hole size Step 5 Assemble the faucet as shown in the diagram NOTE Most sinks are pre drilled with a 1 diameter hole that can be used for the faucet Often if the hole is not being used a plug is inserted into the hole If you do not have a hole or it is already being used for a soap disp...

Page 5: ...o the nipple on the end of the Water Storage Tank and hand tighten Step 1 Apply three rounds of the plumbers tape to the MPT x Press Fit Adapters and then thread the Adapters into the ends of the Polishing Cartridge Use an Adjustable Wrench to tighten Use caution not to over tighten the plastic 1 3 4 5 2 Correct Incorrect HOW TO USE THE BUDDIE FIT PRESS FITTINGS To make easy tubing connections wit...

Page 6: ...3 Open the water tap on the Chrome Faucet and drain all of the water from the Water Storage Tank Step 4 Repeat steps 1 through 3 a second time WARNING DO NOT USE SCISSORS to cut the tubing Scissors will pinch the tubing and it will leak once installed Only use a razor blade or tool designed for cutting flexible water line tubing NOTE The Pressure Sensitive Solenoid has four ports We identify the p...

Page 7: ...off the Chrome Faucet and turn the water supply back on Allow time for the tank to refill Every Two Years Replace the Membrane Cartridge in your RO Filtration Unit or as directed by the manufacturer of your RO Unit CONNECTING A REFRIGERATOR OR ADDITIONAL FILTRATION In some instances it may be desirable to add additional dispensers or further filtration to utilize the filtered water in the Storage ...

Page 8: ...gher than 11 6 Incoming water iron content must be less than 0 2 ppm 7 Do not use outdoors or in a location that subjected to direct sunlight or freezing This warranty will not be effective unless and until the Aquatic Life product is shown to have been used in accordance with the installation and maintenance instructions accompanying the product THIS CONSTITUTES LIFETIME PRODUCTS ENTIRE WARRANTY ...