WARNING
1. READ AND FOLLOW ALL INSTRUCTIONS
2. WARNING: When using electrical products, basic precau ons should always be followed, including the
following:
3. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely
supervised at all mes.
4. Use this unit only for its intended use as described in this manual. Do not use a achments not
recommended by the manufacturer.
5. Never drop or insert any object into any opening.
6. Do not operate this unit without the guard over the suc on fi ng.
7. DANGER: RISK OF ELECTRIC SHOCK. The unit must be connected only to a supply circuit that is protected
bya ground-fault circuit-interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB). Such a GFCI should be
provided by the installer and should be tested on a rou ne basis. To test the GFCI, push the test bu on. The
GFCI should interrupt power. Push the reset bu on. Power should be restored. If the GFCI fails to operate in
this manner, the GFCI is defec ve. If the GFCI interrupts power to the bathtub without the test bu on being
pushed, a ground current is flowing, indica ng the possibility of an electric shock. Do not use this
hydromassage bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a qualified
service representa ve before using.
8. WARNING: RISK OF ELECTRIC SHOCK. A licensed electrician should make all electrical connec ons.
Disconnect power before servicing.
9. WARNING: RISK OF INJURY OR PROPERTY DAMAGE. Please read all instruc ons thoroughly before
beginning installa on, including the following requirements.
10. Follow all local plumbing and electrical codes.
11. INSTALL TO PERMIT ACCESS FOR SERVICING.
12. (For permanently connected units) A green-colored terminal (or a wire connector marked G, GR, Ground,
or Grounding) is provided within the terminal compartment. To reduce the risk of electric shock, connect this
terminal or connector to the grounding terminal of your electric service or supply panel with a conductor
equivalent in size to the circuit conductors supplying this equipment. A pressure wire connector is provided on
the exterior of the pump or control within this unit to permit connec on of a bonding conductor between this
unit and all other exposed metal in the vicinity, as needed to comply with local requirements.
GROUNDING IS REQUIRED
.
The unit must be installed by a qualified service representa ve, and grounded.
Building materials and wiring should be routed away from the pump body and other heat-producing
components of the unit.