Aquatic Access IGAT-180 AD Installation Manual / Instruction Manual Download Page 6

SOCKET INSTALLATION

Some states and localities require the grounding 

of any metal object within five feet of the 

pool edge, but this is sometimes difficult in 

retrofit versus new installations. Each socket 

has a grounding lug on the bottom to connect 

to a grounding rod. Electrolysis (staining of 

the stainless steel) may result if the lift is not 

properly grounded.  Consult your local building 

codes for grounding information.

The socket is located in the seat box and is 

attached under the seat.

A 3” carbide core drill makes an excellent 

clean hole in solid concrete. The center line of 

the socket hole for your installation should be 

_____” from the pool wall or  ______” from 

the edge of the deck. Drill the hole at least 8” 

deep. It is necessary that the top of the socket 

be flush with the deck’s surface. With the socket 

positioned in the hole 

with the notch facing 

the water,

 use a level to be certain the socket is 

plumb and straight, and pour the anchor cement 

around the socket.  Place a combination square 

with level full depth into the socket to assure that the socket is vertical in all directions as the 

cement sets (about 15 minutes). Allow the cement to cure overnight before installing the pool lift.

WATER CONNECTIONS

The pool lift is operated by city/household water pressure with no electricity needed.

Our system is designed for most efficient operation at approximately 55-65 PSI operating (open 

flow) pressure to lift 400 lb., the maximum lift capacity. Less pressure is required to lift less 

weight. 

 There are several ways to determine your water pressure. You can purchase a 0-100 PSI Water 

Pressure Gauge from your local hardware store, or you can ask your water company or fire 

department what the pressure is. Be aware that pressure gauges measure the static pressure of a 

water line, which is higher than the open flow or operating pressure.

2

Summary of Contents for IGAT-180 AD

Page 1: ...Aquatic Access Inc Pool Lift Model IGAT 180 Installation Guide Instruction Manual AquaticAccess com 1921 Production Drive Louisville Kentucky 40299 2110 USA 800 325 5438 502 425 5817 Fax 502 425 9607...

Page 2: ......

Page 3: ...ring to Install Lift Lift Assembly Safety Procedures Service and Maintenance Inspection of Lift Disassembly of Lift Replacement of Piston Seal Replacement of Piston Replacement of Top Guide Replacemen...

Page 4: ......

Page 5: ...t The pool lift should normally be located where there is at least 36 of straight vertical pool wall The depth would need to be greater if there is a curve instead of a right angle at the pool bottom...

Page 6: ...ned in the hole with the notch facing the water use a level to be certain the socket is plumb and straight and pour the anchor cement around the socket Place a combination square with level full depth...

Page 7: ...pacity was tested at lift connection on a baseline unit with operating water pressure while lifting open flow pressure and under ideal mounting conditions pursuant to installation instructions Static...

Page 8: ...nder the seat assembly Attach it to the ends of wheelbase mounting plate with the bolts and nuts supplied with the vinyl liner wall pad When properly adjusted the pad should be flush against the pool...

Page 9: ...eadrest has been ordered follow the same procedure as footrest to install the headrest in the headrest bracket on the seat back Optional seat belts are installed by sliding the belts through the upper...

Page 10: ...is to be left unused for eight hours or longer Always run the seat up and down through several cycles after turning the water supply on This bleeds air out of the cylinder which could cause unexpecte...

Page 11: ...from chlorine and other chemicals in the pool clean the lift only with a soft cloth or Scotchbrite pad After cleaning and rinsing apply car wax and buff to help maintain a bright appearance Never use...

Page 12: ...amp with either Formula 409 or water Never use any oil or petroleum based product inside the cylinder as it will damage the piston and seal 7 Carefully slide piston rod assembly back into cylinder Tak...

Page 13: ...tration Install spacer on piston rod Clean spacer if it is dirty 3 Install piston on end of piston rod using a rubber or plastic mallet Hit bottom of piston until piston is firmly seated Piston should...

Page 14: ...and remove shell 3 Attach seat frame to seat shell and tighten bolts 4 Attach seat to lift and install footrest and head rest REPLACEMENT OF VALVE ASSEMBLY 1 Disconnect water supply 2 Remove hoses fr...

Page 15: ...of the new valve stem and replace stem in valve assembly matching alignment of the protrusion Make certain that the square shaft is completely seated in the square hole Reinsert the valve assembly in...

Page 16: ...eal White gray or brown chalky deposit High pH high total alkalinity high calcium content hard water Clean unit with soft cloth or Scotchbrite pad apply car wax to protect finish Corrosion of Metal Pa...

Page 17: ...sing on or around the lift 6 Do not jump or dive from lift 7 Turn water supply OFF and secure lift with push pin when the lift is to be left unused for eight hours or longer 8 Always run the seat up a...

Page 18: ...ive gallons US per minute at 40 PSI 2 8 Bar to 70 PSI 4 8 Bar maximum pressure ROTATION Automatic 180 Turn MATERIALS 304 316L Stainless UHMW plastic Brass and Rubber OVERALL SIZE HEIGHT 6 2 5 1892 mm...

Reviews: