UNIT CARE AND MAINTENANCE 

 

The Aquatherm Model AT-5000 Aquarium Chiller has been designed to provide 
years of efficient and reliable service with a minimum amount of maintenance.  

 

adthismanual

safetyand
lowedto insurey

 

 

IMPORTANT:  Always remove power from the chiller before 
performing any cleaning or maintenance activities.     

 
CLEANING: 

 

  The condenser fins on the top of the unit must be kept clean for the unit to 

operate properly.  Inspect and clean the condenser fins weekly by wiping with 
a dry cloth, soft bristle brush, or vacuuming.  Be careful not to bend over 
condenser fins. 

 

  The plastic housing cover should be wiped with a soft damp cloth.  Do not use 

any caustic cleaners, as they could scratch of discolor the finish. 

 

  Do not attempt to clean the inner water chambers with any brush that is wire 

wound.  There is a chance of damaging the delicate internal surfaces.  If 
cleaning is required, a separate mild chlorine bleach solution is recommended 
to remove organic material and a dilute solution of muriatic acid is 
recommended for removing mineral deposits.  

Rinse system and all parts 

thoroughly after cleaning before returning unit to service.

 

 

 

adthismanual

safetyand
lowedto insurey

 

 

WARNING: Do not perform both internal cleaning operations at 
the same time as the combination of chlorine and acid may 
cause serious injury or death!  Be sure to wear appropriate 
protection when using chemical cleaners.   

 
 
 
 
 

 
 

Summary of Contents for AT-5000

Page 1: ...AQUATHERM AQUARIUM CHILLER w HEATER OUTLET MODEL AT 5000 INSTALLATION USE CARE MANUAL Aquatherm is a registered trademark...

Page 2: ...NT SAFEGUARDS 1 PRECAUTIONS 2 UNIT CONTROLS INDICATORS AND CONNECTIONS 3 INTRODUCTIONS 4 SPECIFICATIONS 4 UNIT PREPARTATION AND OPERATION 5 7 UNIT CARE AND MAINTENANCE 8 SAFETY GUIDELINES 9 SERVICING...

Page 3: ...nit be used outside of enclosed areas The unit should be used only with a cabinet or stand recommended by the manufacturer 4 Ventilation The unit should be located so that its position does not interf...

Page 4: ...hismanual safetyand lowedto insurey IMPORTANT FAILURE TO FOLLOW THE ABOVE STEPS WILL RESULT IN UNIT DAMAGE AND WILL VOID WARRANTY PRECAUTIONS Do not use oil solvents gasoline paint thinners or insecti...

Page 5: ...ear View Temperature Controller See Pg 7 Lifting Openings Cover Master Switch On Off Compressor Heater On Off Isolator Switch Unit Power Receptacle 1 FPT Water Outlet Port Vent Openings 1 FPT Water In...

Page 6: ...on changes for product improvement without prior notice The performance specification figures indicated are nominal values of production units There may be some deviations from these values and indivi...

Page 7: ...ed if the water piping from the chiller to the aquarium is reasonably close Alternate Placement If space or aesthetic appeal is of concern the unit may be placed inside the tank cabinet if the cabinet...

Page 8: ...check for leakage NOTE Make sure water lines and hoses do not drape over chiller unit to insure water does not leak into unit If leakage is detected check connection fittings on unit If fittings are l...

Page 9: ...cator lights below the LCD display green amber and red These lights indicate the current condition of the system as follows No Lights Illuminated Temperature stabilized to within 5 F of set point and...

Page 10: ...should be wiped with a soft damp cloth Do not use any caustic cleaners as they could scratch of discolor the finish Do not attempt to clean the inner water chambers with any brush that is wire wound...

Page 11: ...ATE PAGE WHEN LIFTING UNIT SERVICING UNIT For service first contact your local dealer or authorized sales agency from which you purchased the unit If unable to contact your nearest representative you...

Reviews: