37
Specification
Hose dimensions
Hose dimensions (inner diameter)
AC 65 / 110
AC 75 up to AC 240
From thru-hull fitting up to feed pump
5/8” / 16 mm
3/4" / 19 mm
From feed pump up to sedimentfilter ( 20/5mic )
1/2“ / 13 mm
3/4" / 19 mm
From sedimentfilter up to high pressure pump
1/2“ / 13 mm
3/4" / 19 mm
Drain over board (Brine
1/2“ / 13 mm
Fresh water flush
1/2“ / 13 mm
Circulation up to cleaning tank
1/2“ / 13 mm
Circulation from cleaning tank to valve no. 1
1/2“ / 13 mm
3/4" / 19 mm
Product water pipe
3/8“ PE pipe, 1/2“ PVC hose
High pressure hose
¼“
Filter
Sediment filter 5 mic and 20 mic
Cartridge 9 7/8“ or 10“ x 2,5“ (250 or 254 mm x 65 mm)
Charcoal filter for fresh water flush
Cartridge 9 7/8“ x 2,5“ (250 mm x 65 mm)
Feed pump Aquatec typ 40
Magnetically coupled centrifugal pump, Power 140/200 Watt
Voltage 220-240 Volt 50/60 Hz, Insulation class E, IP 44. Thermal Protected.
Output 0 m = 1320 l/h, 9.5 m = 600 L/h, 6.0 m = 1200 L/h., 12.0 m =0 Liter.
Note:
For a sufficient pre-pressure in the seawater intake line the head of the feed
pump should not exceed 2 meters.
Low pre-pressure reduces the service life of the pre-filter.
Optional feed pumps with higher head are available.
The pre-pressure in the seawater intake line must not exceed 2.5 bar.