AQUASYSTEM AMH1-15SUS Instruction Manual Download Page 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shut-off operation. 

Avoid  closing  the  delivery  line  valve  when  the  device  is 
operational. Do not operate the device in such state longer than 
3 minutes (time may vary according to liquid

s properties). 

 

 

Use the device in a safe place. 

Keep the pump away from children.

 

 

 

Seek medical attention whenever necessary. 

If you suddenly feel worse when operating the pump, immediately 
discontinue the operation and seek medical attention.

 

 

 

Use protective equipment. 

W

ear protective equipment according to liquid’s safety instructions.

 

 

 

Do not upgrade, reassemble or repair the pump. 

All repair and service related matters are restricted to authorized 
experts.

 

 

 

Prevent chemical reactions. 

When changing the liquid you are going to transfer, remember to 
remove  the  previous  liquid  and  clean  the  device.  Not  doing  so 
may result in dangerous chemical reactions. 

 

 

Place of use. 

Temperature range: 0

40

 

Humidity 80% max. 

 

 
 

Summary of Contents for AMH1-15SUS

Page 1: ...otor Vane Pump INSTRUCTION MANUAL AMH1 15SUS AMH1 20SUS Table of Contents 1 Safety precautions 2 Before using the device 5 Maintenance 6 Dimensions 7 Parts drawings 8 Capacity usage 9 Warranty after s...

Page 2: ...anual misusing the device may result in accidents Keep the manual in a safe place and refer to it when necessary 1 Not following the instructions may result in death or serious injuries Not following...

Page 3: ...ntact with liquid act immediately In case of liquid ingestion skin contamination etc immediately proceed with liquid s safety procedures and seek medical attention It is strictly prohibited to use fir...

Page 4: ...ting the pump immediately discontinue the operation and seek medical attention Use protective equipment Wear protective equipment according to liquid s safety instructions Do not upgrade reassemble or...

Page 5: ...ling with a liquid which should not come in contact with water use an air dryer for the compressed air line In case of moving the device into another place or if there is a new operator please attach...

Page 6: ...te Remember to use an air filter lubricator Recommended available separately Air Filter CKD Brand model F 1000 8 W Lubricator CKD Brand model L 1000 8 W Always make sure that the pressure delivery rat...

Page 7: ...EXTERNAL DIMENSIONS Priming plug...

Page 8: ...PARTS Priming plug Part no 25 differentiates AMH1 15 from AMH1 20...

Page 9: ...through using the priming cap Remember to close it afterwards 2 Check if the flanges piping connections and bolts are not loose 3 Do the same inspection whenever you reassemble the pump 1 If a deliver...

Page 10: ...from the date of purchase Otherwise the service will not be free In both cases covering shipment related costs is customer s responsibility Product s breakdown has been reported within 12 months from...