background image

No.

Description

1.

EXT Pond Pump

Contents

aquascapeinc.com |

CAN (866) 766-3426 |

US (866) 877-6637

3

1

Safety Information

WARNING:

 To provide continued protection 

against risk of electric shock, connect to 
properly grounded, ground fault circuit 
interrupter (GFCI) outlets only, using the 
following guidelines:

(A)   Have a qualifi ed electrician install a properly 

grounded receptacle outlet, acceptable for outdoor 
use and protected from snow and rain.

(B)  Inspect cord before using.
(C)  Do not use an extension cord.
(D)   To reduce risk of electrical shock, all wiring and 

junction connections should be made per local 
codes. Requirements may vary depending on usage 
and location.

(E)   The power cable should be protected at all times to 

avoid punctures, cuts, bruises and abrasions.

(F)   Never handle power cords with wet hands.
(G)  Do not allow the motor to become submerged.
(H)   Never run dry. Never reverse rotation. Never exceed 

an internal case pressure of: 100 PSI.

(I)   Do not wear loose clothing that may become 

entangled in the impeller or other moving parts. 

(J)   Keep clear of suction and discharge openings. 

DO NOT insert fi ngers into pump with power 
connected.

(K)   Do not pump hazardous materials or liquids, such 

as oil, saltwater or organic solvents.

(L)   Do not block or restrict discharge.
(M)   Products returned must be cleaned, sanitized, or 

decontaminated, as necessary, prior to shipment to 
ensure that employees will not be exposed to health 
hazards in handling said material. All applicable laws 
and regulations shall apply.

IMPORTANT:

 Aquascape, Inc. is not 

responsible for losses, injury, or death 
resulting from a failure to observe these safety 
precautions, misuse or abuse of pumps or 
equipment.

WARNING:

 Do not run dry

WARNING:

 Always shut off electrical power 

before installation and/or servicing this pump. 
All electrical wiring should meet state and local 
ordinances. Improper wiring may not only be a 

safety hazard but may permanently damage the motor 
and/or pump. Current motors are only available for 60Hz 
operation.

Summary of Contents for EXT 12000

Page 1: ...U C T I O N S M A I N T E N A N C E aquascapeinc com P R O F E S S I O N A L G R A D E EXT 12000 Pond Pump Item 45049 EXT 18000 Pond Pump Item 45050 EXT 12000 3P Pond Pump Item 45051 EXT 18000 3P Pon...

Page 2: ...late you on your choice of the Aquascape EXT Pond Pumps It has been carefully designed using the advantages of today s technology and carefully constructed to give you the dependability of yesterday T...

Page 3: ...eed an internal case pressure of 100 PSI I Do not wear loose clothing that may become entangled in the impeller or other moving parts J Keep clear of suction and discharge openings DO NOT insert finge...

Page 4: ...e pipe fittings should be self supported and in neutral alignment with each port i e Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute Neve...

Page 5: ...s the motor compressing the seal and hold in place while placing rubber impeller washer over the threaded rod until it bottoms in contact with the motor shaft Impeller metal washer is next placed on t...

Page 6: ...motor and proper wire size according to local electrical codes Check for foreign material inside pump Remove volute and check for impeller rotation without excessive resistance and or noise Remove pu...

Page 7: ...GPH MAXIMUM OPERATING ZONE BEST OPERATING ZONE DO NOT OPERATE Flow Chart MODEL MAX HEAD HEIGHT APPLICATION HEAD HEIGHT 0 5 10 15 20 25 30 35 40 45 50 12000 21 18000 45 18000 17000 16500 15660 14332 13...

Page 8: ...nd mechanical seals This product should only be operated using fresh water without corrosive chemicals like chlorine or bromine If upon Aquascape s inspection the pump shows evidence of a manufacturin...