AquaScape 30214 Installation Instructions Download Page 2

House

Main Plumbing Line

Ball Valve

Booster Pump

Downspout 

Filter

Union

Snorkel and Centipede

H

I

J

F

G

B

B

C

D

E

C

C

A

Bill of Materials for Item #30094, RainXchange™ Booster Pump Kit

(A) #30086 - 2" Tee x 1" FPT - qty. 1 
(B) #98158 - 1" MPT x 1" Slip - qty. 2 
(C) 1" sch 40 PVC x 24" - qty. 3 

(longer lengths may be required)

 

(D) #30088 - 1" slip ball valve - qty. 1 
(E) #30089 - 1" slip x slip union - qty. 1 
(F) #30084/30085 - Booster Pump (not included) 
(G) #30091 - 1" mpt x mpt 1" long nipple galvanized - qty. 1 
(H) #30090 - 1" FPT x 3/4" FPT elbow galvanized - qty.1 
(I)  #30092 - 3/4" mpt x mpt 4" long nipple galvanized - qty. 1 
(J) #30093 - 3/4" FPT Spigot - qty.1 

a q u a s c a p e   r a i n x c h a n g e ™

2

c a p t u r e   >   f i lt e r   >   r e u s e

3

Plumbing Options

There are two different Booster Pump Fitting Kits based on the type of RainXchange

 System pur-

chased (Pondless

®

 Waterfall or Decorative Fountain). Select the appropriate installation section below.

The Booster Pump is required to be housed in a protected enclosure, such as a large valve box, 

faux rock cover, or can be located inside the house or garage. When locating the Booster Pump 

within the house or garage it is recommended that a certified plumber install the pump.

 Note:

 In order for the Booster Pump to properly function, the main water feature pump must be running.

Installation for Pondless

®

 Waterfalls RainXchange

 Systems

Installation

Use the plumbing diagram below to see the complete assembly order of the components.

• 

Cut into the 2” Flex PVC water feature plumbing line and install the PVC tee fitting included 

• 

with the Booster Fitting Kit (item #30094). Follow the plumbing installation diagram for 

proper configuration.
Use the supplied PVC pipe or supply your own rigid or flex 1” PVC to run the plumbing to  

• 

the location of Booster Pump. 
A ball valve is included with the plumbing kit to allow the water supply to be shut-off to the 

• 

Booster Pump when removing for service. 

Note:

 It is recommended to install the ball valve 

as close as possible to the plumbing tee off the main water feature line if the project is 

located in regions that experience freeze/thaw. 
A union is included to allow easy removal of Booster Pump for service or winter storage  

• 

and should be positioned as close as possible to the Booster Pump.

Operation

Before using your RainXchange

• 

 Booster Pump, you must prime the pump first. To do 

this, simply make sure that your Aquascape water feature pump is running. Next, rotate 

the red knob on top of the Booster Pump counterclockwise until water begins to trickle 

out. Then simply tighten the knob back down by turning it clockwise and you are ready  

to use the Booster Pump. 

Top View

Reviews: