Using your AquaPurr eC 

First use of AquaPurr eC 

During the first few uses, some air may spurt out with the water. 
This is caused by air bubbles in the tube and is normal. Once the 
air bubbles pass through the tubing, the spurting will stop. 

For regular use of faucet 

To use your faucet after the 
AquaPurr eC is installed, simply turn 
the diverter valve to the up and 
down/vertical position, and water 
will then flow from the faucet for 
your use.

 

For AquaPurr eC use 

After you finish using your faucet, 
leave the cold water on and always 
switch the diverter valve back to 

“AquaPurr mode” by turning the 

valve to the sideways/horizontal 
position. 

Regardless of how high you turn on the faucet, the 
AquaPurr eC will provide only a dribble of water. So, it is 
recommended that you simply turn your faucet to a low 
water flow when using the AquaPurr eC.

 

 

 

About the sensor 

Proximity sensor 

The sensor is a proximity-type sensor.  If any object is within the 
sensor range, about 6-12 inches, the AquaPurr will turn on. 

How long will it stay on? 

As long as the sensor detects any object in its range it will stay 
on.  It will turn off as soon as it no longer detects anything. 

Why is it clicking on and off? 

If you or your cat are just at the edge of the sensor range it will 
cycle on and off.  Move away and it will turn off.  Move closer 
and it will stay on. 

Sensor range adjustments 

If you want to want to change the 6-12

” 

default sensor range, remove the back 
cover of the electronics module.   

Rotate the screw counter-clockwise to reduce the sensor range 
and clockwise to increase the sensor range.  

To restore the 6-12

” default sensor range

rotate the screw 1/4 turn clockwise after 
turning it all the way counter-clockwise.  

 

 

 

 

 

 

Troubleshooting 

A leak between faucet and diverter 
valve, or on swivel point of diverter 
valve.  

Check to ensure there is a rubber gasket 
between the diverter valve and the 

faucet.  

Also, if you’re using an aerator adapter, make sure it 

also has a rubber gasket. 

Finally, the diverter valve may simply not be tightened enough.  
Hold both the diverter valve and its collar and turn them 
together to tighten it further. 

A leak between diverter valve and 
flexible tubing.  

Tighten the nut holding the tubing on to 
the diverter valve.  In this photo, rotating 
the top of the nut away from you will 
tighten it. 

A leak where tubing attaches to base 
of the AquaPurr eC.  
Push flexible tubing further into 
fitting. 

 

 

Troubleshooting 

The flow from the spigot nearly stops.  

The AquaPurr eC is designed to provide only 
a dribble of water.  But if the flow nearly 
stops then the orifice plate needs to be 
cleared.   

This fitting can be removed by holding the 
collar around the tubing while pulling on the tubing. 

The orifice plate is a fitting with a tiny hole in a plate of metal 
and is used to reduce the water flow to a dribble.  If something 

is blocking that hole, it will slow or even stop the flow.  Use a 
toothpick to clear the hole.  You can also try blowing air through 
it. 

If you are unable to clear the orifice plate, contact us and we can 
supply a replacement. 

Why is it clicking on and off? 

If you or your cat, or any other object, are just at the edge of the 
sensor range it will cycle on and off.  Move away and it will turn 
off.  Move closer and it will stay on. 

If you want to reduce your sensor range see the panel above  

titled “About the sensor”.

 

 

 