background image

3

Blower Sizing

The number of holes in the seats and
floor of the spa can be used to
determine the size of the air blower
that will be required for your
application. See Chart 1 for
recommended blower size based on
the number and size of holes.

Water Jet
Applications

The blower can be used to boost the
output of hydrotherapy jets. A venturi
fitting is normally incorporated into
the jet design. The purpose of the
fitting is to allow air to mix with the
water in the jet. The venturi fittings
can be connected together and then
pressurized with air from the blower to
greatly increase the jet action.

www.aquaprosystems.com

New Spa
Applications

It is important to select a water pump
that will supply sufficient flow to the
jets. Consult with the jet manufacturer
for assistance in selecting a pump or
pumps that will accommodate the
number of jets desired in the spa.
Improper sizing can cause overheating
of the pump and blower.

Choose the correct size blower based
on the number of water jets in your
spa (see Chart 1). See the chart below.
Refer to  the installation guidelines for
additional details. 

Winterizing

The blower is designed for outdoor
use. There are no special off-season
requirements for the blower.  In some
spa systems it is possible to protect
discharge lines from freezing by
operating the blower for several
minutes with the spa drained. The
airflow can be used to purge water
from the air lines.

1-877-AQUASYS

Chart 1

Notes

PRO1002403, PRO1502403, PRO2002403,

PRO100120, PRO150120, and PRO200120

Recommended Number of Holes 

at the Following Hole Diameters

1/8 Inch

3/16 Inch

1/4 Inch

76

35

20

100

46

26

150

68

38

Total Hole Area

Square Inches

1.0

1.4

1.8

Blower

Model

PRO100120, PRO1002403

PRO150120, PRO1502403

PRO200120, PRO2002403

Number of

Water Jets

4 to 9

9 to 13

14 or more

Summary of Contents for PRO1002403

Page 1: ...13 7 07 2007 AquaPRO Systems PRO1002403 PRO1502403 PRO2002403 PRO100120 PRO150120 PRO200120 101 Production Drive Harrison OH 45030 877 278 2797 fax 877 289 2963 cs aquaprosystems com www aquaprosystems com OWNER S MANUAL ...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 3: ... other reproductive harm Wash hands after handling GENERAL To reduce the risk of injury do not allow children to use this product unless they are closely supervised at all times Install blower no less than 1 foot 305 mm above the maximum water level to prevent water from contacting electrical equipment Install in accordance with the installation instructions Blower is designed for outdoor use Inst...

Page 4: ...d national codes 1 For electrical ratings see product decal 2 Check the line voltage to make certain it is correct for the blower being used Do not attempt to 2 connect 240 VAC to a 120 volt blower it will damage the blower and void the warranty 3 Refer to the National Electric Code Guidelines for wire size and to prevent electric shock 4 Refer to the National Electric Code Guidelines for proper s...

Page 5: ...pump or pumps that will accommodate the number of jets desired in the spa Improper sizing can cause overheating of the pump and blower Choose the correct size blower based on the number of water jets in your spa see Chart 1 See the chart below Refer to the installation guidelines for additional details Winterizing The blower is designed for outdoor use There are no special off season requirements ...

Page 6: ... orient check valve 1 Check blower voltage requirements make certain line voltage is correct 2 Verify correct wire gage is being used Blower will not start Blower hums but will not run Blower runs but delivers little air Internal blower overload trips Blower runs too slow 1 Power Off 2 Internal blower overload trips 3 Brushes worn out 4 Nuisance trips 1 Rotor locked 2 Brushes worn out 3 Wrong volt...

Page 7: ...01 2 hp 240v 81005 001 6 Discharge and Sleeve Kit 81007 001 1 7 8 16 x 3 4 Plastite Screw 67007 001 8 8 Check Valve 10116 001 1 Ref No Description Parts Number QTY For Replacement Parts call 1 877 278 2797 Address parts correspondence to AquaPRO Systems 101 Production Drive Harrison OH 45030 U S A Replacement Parts List 1 Please provide following information Model number Serial number if any Part ...

Page 8: ...ic legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall AquaPRO or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment...

Reviews: