SPA BLOWER

323302-013  7/07

© 2007 AquaPRO

®

Systems

PRO1002403, PRO1502403, PRO2002403, PRO100120, PRO150120, PRO200120

101 Production Drive, Harrison, OH 45030 877.278.2797 fax 877.289.2963

[email protected]   www.aquaprosystems.com

OWNER'S MANUAL

Summary of Contents for PRO1002403

Page 1: ...13 7 07 2007 AquaPRO Systems PRO1002403 PRO1502403 PRO2002403 PRO100120 PRO150120 PRO200120 101 Production Drive Harrison OH 45030 877 278 2797 fax 877 289 2963 cs aquaprosystems com www aquaprosystems com OWNER S MANUAL ...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 3: ... other reproductive harm Wash hands after handling GENERAL To reduce the risk of injury do not allow children to use this product unless they are closely supervised at all times Install blower no less than 1 foot 305 mm above the maximum water level to prevent water from contacting electrical equipment Install in accordance with the installation instructions Blower is designed for outdoor use Inst...

Page 4: ...d national codes 1 For electrical ratings see product decal 2 Check the line voltage to make certain it is correct for the blower being used Do not attempt to 2 connect 240 VAC to a 120 volt blower it will damage the blower and void the warranty 3 Refer to the National Electric Code Guidelines for wire size and to prevent electric shock 4 Refer to the National Electric Code Guidelines for proper s...

Page 5: ...pump or pumps that will accommodate the number of jets desired in the spa Improper sizing can cause overheating of the pump and blower Choose the correct size blower based on the number of water jets in your spa see Chart 1 See the chart below Refer to the installation guidelines for additional details Winterizing The blower is designed for outdoor use There are no special off season requirements ...

Page 6: ... orient check valve 1 Check blower voltage requirements make certain line voltage is correct 2 Verify correct wire gage is being used Blower will not start Blower hums but will not run Blower runs but delivers little air Internal blower overload trips Blower runs too slow 1 Power Off 2 Internal blower overload trips 3 Brushes worn out 4 Nuisance trips 1 Rotor locked 2 Brushes worn out 3 Wrong volt...

Page 7: ...01 2 hp 240v 81005 001 6 Discharge and Sleeve Kit 81007 001 1 7 8 16 x 3 4 Plastite Screw 67007 001 8 8 Check Valve 10116 001 1 Ref No Description Parts Number QTY For Replacement Parts call 1 877 278 2797 Address parts correspondence to AquaPRO Systems 101 Production Drive Harrison OH 45030 U S A Replacement Parts List 1 Please provide following information Model number Serial number if any Part ...

Page 8: ...ic legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall AquaPRO or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment...