CLEANING

•  The filter screen will clog up over time. Begin by ensuring that the power supply is disconnected from 

the solar panel before attempting any maintenance or adjustment of the unit. Remove the unit from 

the water. 

•  Please clean regularly (at least once a month) to ensure strong water flow. Failure to maintain the unit 

will result in a burnt out motor and other damage. All Aquapro DC Solar Pumps are water cooled. If 

the pump becomes restricted, or blocked, it will overheat and could cause permanent damage. When 

the flow starts to be reduced check and clean if necessary.

•  The motor unit of the pump is encapsulated with epoxy resin and does not need lubrication. Regular 

inspections, cleaning and maintenance of impellor is necessary to ensure longer life

•  Disconnect the tubing/fountain kit from the pump. 
•  Press on the bottom of the filter housing, and meanwhile move the filter housing away from the 

pump.

•  Turn the impeller cover together with flow valve clockwise to the end and then carefully pull the 

impeller cover, and flow valve, away from the pump.

•  Lift out the impellor assembly. Take care not to break ceramic shaft. Clean the impellor with clean 

water and a suitable brush, taking note to remove fine sediment on and around the back end of the 

impellor. Replace the impellor if necessary.

•  Clean the housing and pump with a suitable brush, taking care to clean off sludge, algae and debris.
•  Reassemble the pump in reverse sequence.
•  Reconnect the pump as before.
•  *Be careful not to drop the ceramic shaft while cleaning the impeller as it breaks easily. 

 

IMPORTANT NOTES:

IT IS IMPORTANT TO ENSURE MAINTENANCE IS CARRIED OUT REGULARLY AS THE COOLING PATH INSIDE 

THE MOTOR CAN BECOME CLOGGED. IF THE IMPELLOR ASSEMBLY BECOMES WORN OR DAMAGED IT 

SHOULD BE REPLACED (AVAILABLE FROM YOUR DEALER OR SPECIAL ORDERS). FAILURE TO DO SO MAY 

CAUSE SERIOUS DAMAGE TO PUMP. INSPECT FOR SIGNS OF WEAR AND TEAR.

AQUAPRO Solar AP300_960_1360 Instructions.indd   6

AQUAPRO Solar AP300_960_1360 Instructions.indd   6

13/5/2022   8:26 am

13/5/2022   8:26 am

Summary of Contents for 02AS510

Page 1: ... AU HOTLINE 1300 278 283 PHONE 61 8 6260 1000 EMAIL SALES AQUAPROONLINE COM AU AP300SP AP960SP AP1360SP SOLAR PANEL PUMP KIT INSTRUCTIONS AQUAPRO Solar AP300_960_1360 Instructions indd 1 AQUAPRO Solar AP300_960_1360 Instructions indd 1 13 5 2022 8 26 am 13 5 2022 8 26 am ...

Page 2: ...fountain nozzles included for different effects DESCRIPTION AP300SP AP960SP AP1360SP MAX WATER FLOW IN FULL SUN 310L H 980L H 1360L H MAX PUMP HEAD IN FULL SUN 0 8M 1 0M 2 1M MAX PUMP POWER CONSUMPTION 2 5W 4 5W 10 5W PUMP VOLTAGE RANGE 6 9V 12 24V 12 24V LOW WATER LEVEL CUT OFF YES YES YES ELECTRICAL CURRENT TYPE DC DC DC SOLAR PANEL MAX POWER 3 5W 8W 20W CABLE LENGTH 5M 5M 5M BUILT IN FLOW ADJUS...

Page 3: ... Any damage to the equipment or unmerited operation will bring dangers to the surrounding precincts If there is any damage of the equipment it must not to be used Check appliance for defects regularly For your own safety disconnect from the power supply before any maintenance of any equipment is attempted Always unplug the pump from the Solar Panel when not in use Never pull the cable to disconnec...

Page 4: ...elect a bigger model The solar pump is designed for outdoor use and is powered by a solar panel In order to make the pump work by solar energy the solar panel needs to be placed in direct sunlight with its solar cells facing the sun as much as possible The performance of the pump depends on the sunlight intensity and the incident angle at which sunlight strikes the panel surface The pump has a bui...

Page 5: ...need to utilize hot water to soften the tube and expand the diameter to fit over the riser end Remember to use Stainless Steel hose clamps to fasten the hose on to the Hosetail This is to ensure that the pipe does not blow off at a later time or leak at this point in the plumbing system Direct the hose in your desired direction Place the pump in the desired location Ensure the pump is on a stable ...

Page 6: ...ousing away from the pump Turn the impeller cover together with flow valve clockwise to the end and then carefully pull the impeller cover and flow valve away from the pump Lift out the impellor assembly Take care not to break ceramic shaft Clean the impellor with clean water and a suitable brush taking note to remove fine sediment on and around the back end of the impellor Replace the impellor if...

Page 7: ...AS073 12AS074 7 Solar Panel Only 12AS067 12AS068 12AS069 9 Fountain kit inc Threaded Adaptor Riser Fountain Nozzles N A 12AS071 1 4 7 2 3 5 6 8 9 PART DESCRIPTION NOTE PLEASE CONSULT YOUR RETAILER FOR QUALITY ORIGINAL AQUAPRO REPLACEMENT PARTS FOR YOUR AQUAPRO PRODUCT VISIT WWW AQUAPROONLINE COM AU FOR NEAREST STOCKISTS AQUAPRO Solar AP300_960_1360 Instructions indd 7 AQUAPRO Solar AP300_960_1360 ...

Page 8: ...ic shaft is broken Clean the Impellor Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impellor Shaft worn out Replace Impellor Shaft Impellor broken Replace Impellor Flow adjuster set to minimum Open the flow adjuster and allow water to flow Unit inlet is blocked or the water pump outlet is blocked Clear all blockages The height to which you are pumping ...

Page 9: ...ranty will be void if any of the following events occur as determined by us at our sole discretion Voiding Events any tampering removal of warranty identification labels or electrical components is evident the defect has arisen due to an accident incorrect or inadequate installation misuse or abuse of the product including improper maintenance and service excessive wear and tear not following manu...

Page 10: ...HOTLINE 1300 278 283 PHONE 61 8 6260 1000 EMAIL SALES AQUA A NOTES AQUAPRO Solar AP300_960_1360 Instructions indd 10 AQUAPRO Solar AP300_960_1360 Instructions indd 10 13 5 2022 8 26 am 13 5 2022 8 26 am ...

Page 11: ...OM AU WEB WWW AQUAPROONLINE COM AU AP300SP AP960SP AP1360SP SOLAR PUMP INSTRUCTIONS AQUAPRO Solar AP300_960_1360 Instructions indd 11 AQUAPRO Solar AP300_960_1360 Instructions indd 11 13 5 2022 8 26 am 13 5 2022 8 26 am ...

Page 12: ... SALES AQUA A WWW AQUAPROONLINE COM AU HOTLINE 1300 278 283 PHONE 61 8 6260 1000 EMAIL SALES AQUAPROONLINE COM AU AQUAPRO Solar AP300_960_1360 Instructions indd 12 AQUAPRO Solar AP300_960_1360 Instructions indd 12 13 5 2022 8 26 am 13 5 2022 8 26 am ...

Reviews: