background image

SALT: MAXIMUM SALT LEVEL

The high salt level light will begin flashing as the level approaches the upper end
of the ideal range. Operating the unit at higher salt levels would be of no benefit
and these higher levels may affect other pool equipment.

As above, the salt level light will begin flashing as the level 
 approaches the upper end of the ideal range. 

 

Operating the unit at higher than recommended Salt levels will reduce  

cell life and it’s ability to self clean.

When do I need to dilute the water?

If the maximum salt level light is flashing, have a sample of water tested by a pool 
professional.

If the salt level Is 20% higher then the Ideal recommendation, dilute the water.
Dilute if salt level is 4000ppm or higher

INITIAL SALT DOSAGE

Simply use the following formulas to calculate the amount of salt required.

   Add 21 lbs. of salt for every 1,000 gal (3785 litres) of water

Example:

 Pool volume is 20,000 gallons.

 

25 lbs. of salt for every 1,000 gal. of water

 

Multiply 2.5 x 20 (thousand gallons) = 425 lbs. of salt

11

Type of Salt  

 

                                                                                                   

Use Feed grade type salt whenever possible.  Use salt that does not contain yellow
Prussiate of Soda. (Prussiate of soda is an anti-caking agent.  This may cause
yellow stains on your pool or spa bottom if left on the bottom without being dis-
solved).  Salt should be in granular form similar to table salt.                                      
              

How to add 

   

                                                                                                                     

Never add salt to the skimmer box, this will not harm your Aquapower-plus salt
chlorinator however coarse salt granules may seize the pump impeller.

Always disconnect any automatic cleaners before adding salt and leave them off 
until the salt has fully dissolved. Cleaners too may be affected by the coarse gran-
ules and because the salt solution initially formed is denser than water, it remains at 
the bottom of the pool. If an automatic cleaner operates through this dense solution, 
the cleaners suction hose will drop to the floor and may be damaged as a result.

Cut open bags (normally 50 lbs.) and pour into pool away from skimmer and suction 
points. Brush with a pool brush to dissolve quickly.

Do not use salt that contains yellow prussiate of soda. This may cause yellowing 

on 

pool surface.

RECOMMENDED SALT TYPE & HOW TO ADD

Installation guide

If the cell is installed horizontally,  both the inlet & outlet sockets need to face 
downwards. This may only be achieved by plumbing 90 degree elbows on either 
end of the cell so that they face downwards. Refer to diagram.  If you are having 
a vertical installation follow the guide on the next page. 

Water may flow ONLY in the direction specified on the cell.

Use 2” to 1-1/2” reducers if installed in 1-1/2” plumbing.

Caution: Use only standard type ‘N’ plumbing adhesive. Contact Aquapower-plus if 
you are unsure of what to use.

The cell must be installed on the pool return line downstream of all other equipment 
and or equipment take-off and return points. That is after the pump, filter, solar sys-
tem, heater or other receptacles where in excess of 3/4 oz. of gas could accumulate.

If an air blower is connected directly to venturi spa jets, a vented loop must be 
installed. This allows any build up of hydrogen gas to escape from the blower line 
before it becomes in contact with the blower motor. (Contact Aquapower-plus for 
plumbing advice) Ensure sufficient space is kept free for removal of the cell for 
inspection purposes.

Where the cell is installed below water level, ensure valves are installed so the water 
can be isolated for flood free removal of the electrode.

Ensure the male key-way situated on the electrode cap is positioned into the female 
keyway situated on the clear cell body before screwing on the locking nut.

18

Summary of Contents for AP12RP

Page 1: ...Return to Pet Pool Products Inc 305 Comstock Suite 2 3 Chandler AZ 85225 Postage needed ...

Page 2: ...On Off settings must be in 24 hour format i e 6 00pm 18 00 hrs The chlorinator will not accept an operating time period which travels from PM to AM through midnight If you would like the unit to operate on automatic through midnight you must use two time periods For Example To turn on at 9pm and turn off at 9am On 1 set to 21 00 Off 1 set to 23 50 On 2 set to 00 00 Off 2 set to 09 00 The first time...

Page 3: ...HASING THIS QUALITY PRODUCT Manufactured and distributed by Pet Pool Products Inc 305 Comstock Suite 2 3 Chandler AZ 85225 Local 480 635 8197 Local Fax 480 635 8359 Toll Free 1 866 725 8766 Toll Free Fax 1 866 807 5546 www aquapowerplus com ...

Page 4: ...NOTES 27 ...

Page 5: ... models will have a 1 year warranty on power supply and electrode if installed in a commercial situation Extended Warranties are available Please see your Dealer Residential Extends warranty to a full 5 years on entire unit Parts and Labor Commercial Extends warranty 1 year per warranty purchased Commercial pools can purchase as many years as they require Special Conditions On site labor service c...

Page 6: ...linity of approx 4500 to 6000 ppm and fresh water is zero It is the similarity between the salinity of the human body and that of a salt pool that make for a silky luxurious swimming experience The chlorinator comprises two basic components the power supply and cell Elec trode It is within the cell that the electrolytic reactions occur Chloride ions in the water are converted into chlorine gas thi...

Page 7: ...s to build on the electrode contact Aquapower plus for advice 5 Always disconnect automatic pool cleaners when adding salt and only reconnect when salt has fully dissolved 6 DO NOT USE COPPER OR BROMINE BASED PRODUCTS IN POOL Usage of these may void warranty Consult your local pool professional for advice Some copper based products available are acceptable for use consult with your pool profession...

Page 8: ...ut is displayed Use UP Down buttons to alter time ON1 is displayed wait to see ON1 time Use UP Down buttons to alter time OFF1 is displayed wait to see OFF1 time Use UP Down buttons to alter time ON2 is displayed wait to see ON2 time Use UP Down buttons to alter time OFF2 is displayed wait to see OFF2 time Use UP Down buttons to alter time ON3 is displayed wait to see ON3 time Use UP Down buttons ...

Page 9: ...trode from box 2 If you have not purchased the optional stand than you must mount your power pack in a suitable location fence post block wall etc in close proximity to your existing pool equipment 3 Mount the mounting bracket in appropriate location using the supplied screws and anchors 4 After hanging the power box You may proceed to the cell installation 5 You may either run pvc piping to cell ...

Page 10: ...will automatically lock it in 3 You must then set an OFF1 time Push the view button until OFF1 appears wait a moment and the corresponding OFF1 time will be displayed Initially this time may read 00 00 push the UP or DOWN once the display will begin to flash indicating it is in the set mode 4 Press the UP button to adjust the time that you would like the pump and chlori nator to switch off Wait 30 ...

Page 11: ...erent tolerance levels to operating dry or in a starved condition The average delay time would be from 3 to 6 minutes but we would recommend you seek advice from the pump manufacturer or a pool professional To deactivate the pump monitor hold the DOWN button until the flashing delay time is on display Use the DOWN button to reduce the time to zero this disables the protection monitor Note Remember ...

Page 12: ...olling message the display will show the maximum percentage output that it is able to attain CLEAN CELL or Lo SALT This message will cease when the salt level is topped off sufficiently or the electrode is cleaned or both Note It Is good practice to have your pool water tested by a pool profes sional on a regular basis Despite lasting many years chlorinator elec trodes have a limited life If an ele...

Page 13: ...med is denser than water it remains at the bottom of the pool If an automatic cleaner operates through this dense solution the cleaners suction hose will drop to the floor and may be damaged as a result Cut open bags normally 50 lbs and pour into pool away from skimmer and suction points Brush with a pool brush to dissolve quickly Do not use salt that contains yellow prussiate of soda This may caus...

Page 14: ...ater Reinstall cell connect terminals open valves and switch on power Turn unit back to auto or on position SAFETY Your AquaPower Plus chlorinator must be installed in accordance with the installation instructions listed in this manual The cell apart from producing chlorine produces a mixture of gases primarily hydrogen Hydrogen is not readily dissolved into the water and under normal filtration co...

Page 15: ...e residual of 1 5ppm to 3 0ppm should be maintained This level will alter with respect to bather load debris falling into the pool and the pools water temperature These factors alter the demand for chlorine as will the water balance and filtration s effectiveness Refer to equipment manufactures specifications with regard to maximum chlorine level permissible The percent of chlorine output is display...

Page 16: ...strongly recommend you seek advice from a pool professional regarding the balancing of water for your pool A correctly balanced pool will protect It and the equipment from chemical damage and ensure bathers are swimming In clean clear healthy pool water 14 CYANURIC ACID CHLORINE STABILIZER The sun s ultraviolet light breaks down chlorine with this in mind it is essential in sunny climates to use a...

Reviews: