Performance Data Sheet
Important Notice:
Read this data sheet and compare the
capabilities to your actual water treatment requirements.
The performance of this product has been verified and
substantiated as the test data below summarises.
These substances may not be in your water.
Replacement component: AQP-RFW
1. This system requires regular replacement of the filter
cartridge to maintain proper operation. Performance
will vary based on local water conditions.
2. This system must be installed according to local
plumbing codes on the cold water line.
Substance
Average Influent
Reduction
Requirement
Average product
water concentration
Average % Reduction
Max. Effluent
Chlorine, Taste & Odour
2mg/L
75%
<0.1
>99%
<0.1
Particulate Class I 1um
N/A
85%
N/A
99.8%
N/A
Turbidity
11.45 NTU
<1.0 NTU
<0.1 NTU
>99%
<0.1 NTU
Cyst
N/A
99.9%
N/A
99.9%
N/A
Class
Treatment Type
Function
Pass
I
Microbiological status bacteriostatic
Will stop bacteria increasing, but will not remove
them unless ii (a) is ticked
N/A
Ii
Microbiological treatment
Ii (a)
Bacteria removal
Will remove or inactivate bacteria
N/A
Ii (b)
Virus removal
Will remove or inactivate virus
N/A
Ii (c)
Protozoa removal
Will remove or inactivate cryptosporidium & giardia Pass
Iii
Turbidity & particulate reduction
Will reduce cloudiness
Pass
Iv
Taste & odour reduction
Will reduce taste and odours
Pass
V
Chemical treatment
Will decrease chlorine compounds
Pass
This product complies with AS/NZS 3497 & AS/NZS4348 for the following water treatment processes: Treatment and Tests Table C1
To a capacity of 10,000L