If the degree of demineralization is reduced after changing or servicing the reverse 
osmosis membranes, it is possible if the membranes are damaged or installed not 
correctly. 

7.6.3

 

This RO system has the function of low pressure protection. If the pressure of 

the raw water or water after the pre-filtration are below the minimum operating 
pressure, the RO system will stop. 

7.6.4

 

Never close the regulator of concentrate and\or the pump valve completely. 

This will lead to a sudden increase of pressure and damage to the RO system. 
Also the system will be under high pressure, it is not safe for service staff

7.6.5

 

The conductivity meter installed on the purified water, allow you to see the 

effectiveness of the RO system. 

7.6.6

 

At the first start-up it is necessary to drain purified water to flush the RO system. 

 

7.7

 

Maintenance operations at shutdown 

7.7.1

 

Short shutdown (1 ~ 3 days) 

When the ambient tempe

rature is 5 ~ 35 ° C, you can turn 

off the system as a normal 

shutdown.   After turning the system on, the RO system should operate for at least 1 ~ 
2 hours

7.7.2

 

Long shutdown period (more than one week) will require the following steps: 

7.7.2.1

 

Soak the membranes in a 1% solution of sodium bisulfite. 

7.7.2.2

 

Soak the membranes in 0.5% formaldehyde solution (it is not recommended 

to use this chemical for installations operating in the food and medical industries). 

7.7.2.3

 

If the ambient temperature is below 0 ° C, it is necessary to 

add antifreeze. 

Sodium bisulfate    2% 
Propylene glycol    40% 
Clean water            58% 
This solution passes through the RO system. Drain the liquid chemical agents in 
conjunction with the flush water for 3 minutes. Stop the pump and close the RV-01, 
RV-02 and RV-03 valves. This solution must be replaced after 2 months maximum. If 
the shutdown period is more than 2 months, you must fill in a fresh solution. 

7.8 Mode of operation 

The unit has two modes 

 automatic and manual (CIP). Fully automatic operation is 

operated by the RO controller, the water level sensor, the pressure sensor and the 
TDS meter. In most cases the system is able to provide a continuous supply of water 
automatically. 

Summary of Contents for APRO S-125

Page 1: ...toi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com REVERSE OSMOSIS SYSTEM APRO series Installation and operation...

Page 2: ...ystem Aquaphor 7 INSTALLATION REVERSE OSMOSIS SYSTEM 7 1 Attention 7 2 Connection 7 3 Start up 7 4 Security measures 7 5 Commissioning 7 6 Operation 7 7 Maintenance operations at shutdown 7 8 Mode 8 C...

Page 3: ...ater treatment For proper operation it requires pretreatment Materials of RO systems are safety non toxic and do not release to the water any dangerous substances to health or the environment 2 ASSIGN...

Page 4: ...verse osmosis system Aquaphor model T RO X Y L Z Q Q Designation Content designation Transcript notation T Trade name availability AP Aquaphor Professional RO Type of system Reverse osmosis X Type of...

Page 5: ...of elements AP RO S 125 AP RO S 250 AP RO S 375 AP RO S 500 F01 F02 Filter housing Gross10 20 2 2 2 2 Polypropylene 5 mkr 1 1 1 1 Carbon filter B510 520 13 1 1 1 1 LPS 01 LPS 02 Low pressure switch P6...

Page 6: ...REATMENT L Tolstoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com Control panel 220 380 1 1 1 1 Frame 1 1 1 1 Pas...

Page 7: ...trate NPT 5 REQUIREMENTS FOR THE QUALITY OF SOURCEWATER 5 1 Chlorine If the water is chlorinated you need to install a carbonfilter 5 2 Hardness If water hardness exceeds 20 ppm it is necessary to est...

Page 8: ...Not more 5 SDI Mineral oil Salinity TDS 5000 mg l Fe total Not more than 0 1mg l Oxidizers chlorine ozone KMnO4 Not more than 0 1 mg l Manganese Mn Not more than 0 05 mg l Organic impurities Not more...

Page 9: ...rder to keep the water feed rate and also to avoid ingress of chlorine solid particles in the membrane modules Replacement instructions Shut off the system from electricity make sure there is no press...

Page 10: ...cteria and other impurities from the water with the aim of purification or desalting It is based on the principle of separation of permeate clean water and concentrate dirty water through the membrane...

Page 11: ...RV 01 Pump pressure regulation valve LPS01 Low pressure switch RV 02 Concentrate flow regulation valve LPS02 Low pressure after filtration RV 03 Recirculation flow regulation valve XV 01 Solenoid inl...

Page 12: ...tional 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Technical drawing of a reverse osmosis system Aquaphor model AP RO S 125 Technical...

Page 13: ...tional 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Technical drawing of a reverse osmosis system Aquaphor model AP RO S 375 Technical...

Page 14: ...nstalled should be between 4 45 C The level in the tank with permeate must not be higher than 1 5m above the level of the permeate line exit from the membrane otherwise the system may malfunction for...

Page 15: ...ed 7 4 5 It is forbidden to make any installation and or change of the system whileit works 7 5 Commissioning 7 5 1 Prepare to work carry out in manual mode New RO membranes are soaked with conserving...

Page 16: ...tment and reduce the life of the RO membranes 7 5 3 Check the working pressure and compare it with the results of the first test and the technical characteristics 7 5 4 Check the presence of water at...

Page 17: ...7 7 1 Short shutdown 1 3 days When the ambient temperature is 5 35 C you can turn off the system as a normal shutdown After turning the system on the RO system should operate for at least 1 2 hours 7...

Page 18: ...d is activated by turning in the direction of the arrows which is drawn on it typically clockwise To re power the RO system is necessary to press the switch EMERGENCY STOP To reset the conductivity co...

Page 19: ...lve it displays as ON state M2 high pressure pump Indication of the high pressure pump displays as ON state FLUSH VALVE flushing valve indication of the flush solenoid valve displays as ON state FULL...

Page 20: ...e error lights the lamp ALARM Display panel controller SET button parameter setting selection of the parameters to change the display circular selection discharge thousands hundreds tens and units sel...

Page 21: ...connection will damage the contact or shorten its life Designation ZJ intermediate relay CJ magnetic contactor The drawing shows the connectors which are located on the rear panel The panel is equippe...

Page 22: ...is not used lock out the contacts 5 and 8 6 The reset signal can be connected to the reset button on the control panel which uses to unlock and reset the alarm in the event of high or low pressure 8 t...

Page 23: ...of 0 99 hours If set to 03 the system will flush the membrane every 3 hours of continuous operation or standby mode If you are not satisfied with the parameters you can change them using the buttons a...

Page 24: ...art with a pause which you choose when the valve is fully closed This is done with a purpose in order to prevent shutdown of the system by work out sensors feed water and exhaustion the formation of a...

Page 25: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Page 26: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Page 27: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Page 28: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 380...

Page 29: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Page 30: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Page 31: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Page 32: ...stoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Electrical drawings 230...

Page 33: ...www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Dimensions specifications of reverse osmosis system Aq...

Page 34: ...tonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT Dimensions specifications of reverse osmosis sys...

Page 35: ...e air d Flushing valve is switch on Check the operation of the pump after flushing 4 Very loud pump opera tion sound when pres sure grow up a Control block or element of posting valve Check and replac...

Page 36: ...han 1 the tank is filled by 1 2 2 3 of the flushing solution Also you must have T branches and locking valves on the line of the permeate product and concentrate with outputs for flexible hoses not in...

Page 37: ...raining the permeate to the drain for at least 15 min control the TDS parameter shown on the TDS meter q If all indicators of devices are normal switch the valves of permeate line into operation posit...

Page 38: ...are not more than 3 months from the beginning of operation Lifetime of membrane is 1 year from the beginning of operation Warranty period The warranty period of the RO system is one year from the date...

Page 39: ...L Tolstoi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT 12 CE CERTIFICATE...

Page 40: ...oi 2A Sillam e 40231 Estonia www pro aquaphor com International 372 356 2204 21 Skype aquaphor market pro e mail market pro aquaphor com AQUAPHOR PROFESSIONAL WATER TREATMENT 13 EC DECLARATION OF CONF...

Reviews: