Connect all hoses to and
from the Steam generator.
The appropriate outlets/
inlets are labeled in the
diagram and are visible in
the photo. The Steam
generator drain hose is
pushed onto the fitting
(straight
or
elbow)
connected to the Steam
Generator. It is
secured to this fitting by a
clamp and a 3/16 X 5/8
inch round head fastener
as is shown in the above
figure. It is also shown
assembled in the photo
below.
Front and side view of Steam outlet
Black insulated hose
Connect the insulated black high temperature steam pipe,
which comes from the steam outlet of the steam generator, to
the steam jet’s connector on the spa’s back panel.
The all silver water supply hose
threads in here
Electrical feed
Steam generator
Electrical
break-out
Black insulated
steam hose
When bending the insulated steam hose, please Use
Extreme Care not to crimp the hose as you feed it
through the appropriate hole in the tub section. (as
shown on next page) Also insert the larger rubber
washer (as pictured in the parts page
of this manual) into the connector
before threading it into place on the
steam jet.
Steam outlet
Steam drain
Steam generator plumbing
Summary of Contents for Mazatlan
Page 1: ...Mazatlan INSTALLATION MANUAL...
Page 4: ...Page 3...