background image

 

Tank Monitor Quick Start Guide      

Revision A August 2012 

Thank you for purchasing an Aquamonitor product.  
Please read this guide carefully and keep it for future 
reference.  The details included in this guide, such as 
pictures, symbols and descriptions are for reference 
only and may not exactly represent the physical detail 
of your item.  This is because we are continually 
updating and improving Aquamonitor products and so 
features, technical specifications and physical 
appearance are subject to change. 

Safety and Usage Precautions 

Please read and understand all instructions contained in this 

guide prior to installation and use.  If clarification or further 

details are needed, contact us at 

www.aquamonitor.com.au

This product is a radio transmitting device and may cause 

interference with sensitive electronic equipment such as audio, 

visual, vehicle and medical equipment and systems.   

 

This product is also a radio receiving device and may be 

affected by other equipment or systems that emit radio 

frequencies, such as two-way radios, wireless remote 

controllers and in-home wireless products. 

 

Always ensure safe working conditions during installation.  If 

using a ladder, make sure it is on firm and level ground and 

that a second person is holding it steady.   

 

Only use the DC power adaptor supplied with the Display Unit.  

Do not use other types as this may damage the electronics. 

The Display Unit is not waterproof and contains sensitive 

electronic circuitry.  Use it only in dry, cool environments. 

 

The Display Unit and sensors operate at low radio power levels 

to ensure good battery life.  Locate the Display Unit as close 

as possible to the sensors to ensure wireless operation.  Avoid 

locating the sensors or Display Unit within or near metallic 

structures.  Ensure that there is clear space around the 

sensors and Display Unit to allow the radio signals to 

propagate.  Install the sensors in locations away from areas 

that fill or pool with water.  

 

When replacing batteries please ensure that the batteries are 

the type specified in this guide.  The sensors will not operate 

and may be damaged if the battery voltage is incorrect. 

 

If this product does not operate normally then refer to the 

troubleshooting information contained in this guide. There are 

no operator serviceable parts inside aside from batteries. 

Please refer servicing and repair to qualified service personnel 

or seek support through the Aquamonitor web site. 

 

The Aquamonitor Tank Sensor is designed to suit a variety of 

tank styles and types.  Please check that your tank height is 

within the range limits as detailed in the Specifications.  The 

Tank Sensor requires a clear line of sight to the water surface 

from the top of the tank and objects within the path of the 

sensor to the water surface will affect level readings. 

 

All rights are reserved.  No part of this document may be 

photocopied, reproduced or translated into another language 

without the written consent of Aquamonitor Pty Ltd. 

 

The information contained within this manual is subject to 

change without notice.  Aquamonitor Pty Ltd shall not be liable 

for errors contained herein or for consequential damages in 

connection with the furnishing, performance or use of this 

guide or of associated information. 

 

 

General Specifications 

Wireless range 

50 metres line of sight 

30 metres urban location 

Operating temperature 

5 to 45 Celsius 

RF (radio) Output 

10mW approx. 434 MHz 

Battery Type 

2 x AA 1.2V – 1.5V, 2200mAh 

DC Power – Display Unit 

5V DC, 200 mA 

Tank level range 

0.3 to 3.1 metres 

 

LED Indicators 

Sensor 

LED flashes on battery insert 

LED flashes every minute

 

 

Boot up OK 

Wireless connection OK 

Display Unit 

All buttons blue 

Arrow buttons stay on (blue) 

OK button is red 

OK button is green 

OK button is flashing red 

 

Wake mode 

Stopwatch is running 

Consumption above set limit 

Consumption below set limit 

Alarm condition  

Features 

 

Display of water consumption: daily, per person, average 

and quarterly. 

 

Graphical display of consumption: 24 hour consumption, 7 

day consumption. 

 

Configurable alarms: low tank level, time alarm 

(prolonged usage), night-use alarm. 

 

Status Bar display of date and time plus sensor wireless 

connection status and sensor battery level. 

 

Navigation bar with display of button functions. 

 

Illuminated buttons for indication of consumption limit 

and alarms.

 

Information Display  

 

1 - Status Bar with sensor health indicators. 

2 - Title Bar, describing the value displayed. 

3 - Value displayed, updates every minute. 

4 - Seven day history of the displayed value. 

5 - Navigation bar showing button functions. 

 

Button Operation – Navigation Bar 

 

The function of each button is shown on the navigation 

bar (see item 5 in the above figure). 

 

The first button press will activate the backlight and 

illuminate the buttons (blue). If there is an alarm then the 

alarm sound will be cancelled 

 

Pressing OK will activate the menu system which allows 

display of graphs and changes to settings. 

 

Please note that the stopwatch function only works with 

Mains Sensors.

 

 

 

Reviews: