34
11.4
Settings list
Menu level 1
Menu level 2
Menu level 3
description
value
OutPutS
Digital outputs
Fc
select function
Impulse
IMPULS
digital output pulses
SG
select output signal
Volume
UP
pulse value (
0.01
, 0.001-1000)
0.01
MS
pulse width (
20
, 2-500)
20
LIMIT 1
1 point limit switch
SG
select signal the limit applies
L1
limit value; (
Qcont
, 0 to full range of size)
HY (+/-%)
hysteresis of value (
5
, 0.0-99.9)%
Ac
acting logic function (
NO
/NC)
LIMIT 2
2 point limit switch (min/max)
SG
select signal the limit applies
L1
limit value min (
Qmin
, 0 to full range of size)
L2
limit value max (
Qcont
, 0 to full range of size)
HY (+/-%)
hysteresis of value min / max (
5
, 0.0-99.9)%
Ac
acting logic function (
NO
/NC)
StAtuS
acts on alarm or error status
Ac
acting logic function (
NO
/NC)
Int-BUS
Internal bus communication in single mode
Fc
select function
Modbus
ModbuS
Modbus RS485
Ad
Address (
1
, 1-247)
1
BA
Bauderate
9600
PA
Parity
None
M-BUS
M-Bus RS485
Ad
Address; (
0
, 0-250)
SE
Secondary address
BA
Bauderate
UnItS
Units
V
units for volume
V
Vd
decimals for volume value
0.001
M
units for mass
Kg
Md
decimals for mass value
0.001
Qv
units for volume flow
L/h
Qm
units for mass flow
Kg/h
t
units for temperatur
°C
VP
units for volume pulse
L
MP
units for mass pulse
Kg
ConFIG
System configuration
CM
fuel compensation
off
tt
temperature threshold (
60°C
, 20-90)
60°C
SYSINFO
System Information
SN
########
Serial number
tA
########
Customer tag name
CF
0.0000
correction factor (%)
FW
00.00.00
Firmware version