AquaMedic M-Ventil Standard Operation Manual Download Page 5

 

 

5

1.

 

Body of the valve 

2.

 

Magnetic reel 

3.

 

Power cord 

4.

 

CO

2

-inlet 

5.

 

CO

2

-outlet 

6.

 

Now,  a  tube  is  mounted  in  the  same  way  on  the outlet  (5).  Here,  you  do  not  need to  use  a 
pressure tube, you may use ordinary PVC-tube (6/4 mm, ¼“).  

7.

 

The free end is connected to the bubble counter inlet or to the CO

2

–inlet. 

8.

 

If you use a pressure regulator with adjustable operating pressure, set it to 1 – 1.5 bar.  
 

Note:

 

Always 

use 

non-return 

valve 

between 

the 

aquarium 

and   

solenoid 

valve. 

It 

prevents 

water 

from 

flowing 

back 

from 

the 

aquarium  

into  the  regulator  and  the  CO

2

–bottle  and  may  cause  damage.  We  recommend  

to use the original Aqua Medic bubble counter with integrated non-return valve. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

3. Operation with timer 

 
The  CO

2

–consumption  during  the  day  (light  phase)  is  determined  primarily  by  the  plants.  In  the 

night  (dark  phase),  the  plants  excrete  CO

2

–gas.  So  it  is  not  necessary  to  provide  CO

during  the 

night  time,  it  may  even  be  harmful.  The  solenoid  valve  can  be  linked  to  a  timer  to  meet  these 
specific  requirements.  An  elegant  solution  is  to  connect  the  solenoid  valve  to  the  timer  that 
controls the light. The valve is then switched on and off together with the light.  
 

4. Operation with pH controller 

 
This  operation  mode  should  be  preferred  in  comparison  to  others.  It  is  the  most  exact  and 
economic version. Only the exact quantity required is fed into the system. It balances the loss that 
is,  for  example,  caused  by  water  movements  and  aeration.  Fluctuations  of  the  pH-values  are 
avoided  by  an  electronic  control.  This  is  an  advantage  for  the  creation  of  a  well-balanced 
environment. 
 

5. Operation with water 

 
The  Aqua  Medic  solenoid  valve  may  also  be  used  for  the  control  of  smaller  reverse  osmosis 
systems. Some important points have to be taken care of to avoid mistakes and damages: 
 

-

 

The reverse osmosis unit should not exceed the capacity of 150 l/day (35 gpd) of pure water. 
The small opening of 2 mm will cause pressure drops and decrease the capacity, if used with 
larger systems. 

 

-

 

If used with tap water, the solenoid valve may be blocked by dirt and rust. In order to avoid 
this, several precautions have to be taken:  

 

-

 

The  solenoid  valve  has  to  be  connected  between  the  sediment  filter  and  the  RO  module  to 
protect  it  from  clogging.  The  storage  tank  where  the  water  is  collected  should  have  a  safety 
outlet  to  the  drain.  If  used  for  saltwater  aquaria,  the  evaporated  water  should  not  be  refilled 
directly from the RO unit. It is recommended to collect the RO water in a separate tank and to 
provide the aquarium from this tank. 

 

-

 

The solenoid valve may not be operated with saltwater or pure water (reverse osmosis). 

 
 

Summary of Contents for M-Ventil Standard

Page 1: ...as Leitungswasser Anschluss Schlauch 6 4 mm Spannung 230 V Leistungsaufnahme 2 5 Watt Einschaltdauer 100 2 Betrieb f r CO2 Auf und Einbau Das Magnetventil ist fertig montiert und gepr ft Es muss nur n...

Page 2: ...st die genaueste und die wirtschaftlichste Die Regelung dosiert stets nur soviel wie verbraucht wird Sie gleicht auch den Verlust aus der durch Wasserbewegung oder Bel ftung verursacht wird pH Schwank...

Page 3: ...me mit Ihrem Ger t auftreten wenden Sie sich bitte an Ihren Fachh ndler Diese Garantie gilt nur f r den Erstk ufer Sie deckt nur Material und Verarbeitungsfehler die bei bestimmungsgem em Gebrauch auf...

Page 4: ...ass Nominal width 2 mm 0 08 Operating pressure 0 4 bar Medium gas tap water Connection flexible hose 6 4 mm 1 4 Voltage 230 V if not otherwise noted Power consumption 2 5 Watts Operating factor 100 2...

Page 5: ...mode should be preferred in comparison to others It is the most exact and economic version Only the exact quantity required is fed into the system It balances the loss that is for example caused by wa...

Page 6: ...he model number and date of purchase This warranty may not apply if any model or production number has been altered deleted or removed unauthorised persons or organisations have executed repairs modif...

Page 7: ...le 6 4 mm 1 4 Tension 230 V Consommation 2 5 Watts Protection d utilisation 100 2 Utilisation avec CO2 Montage et installation L lectrovanne est pr mont e et test e Il reste uniquement adjoindre le sy...

Page 8: ...a ration ou au brassage de l eau Les variations du pH sont vit es gr ce un contr le lectronique C est l id al afin de cr er un environnement stable et quilibr 5 Utilisation avec un osmoseur L AB Aqua...

Page 9: ...z vous votre revendeur Cette garantie n est valable que pour le premier acheteur Elle ne couvre que les d fauts de mat riaux ou de fabrication qui peuvent appara tre dans le cadre d une utilisation no...

Reviews: