AquaMedic KR 20000 Operation Manual Download Page 6

 

6

As  soon  as  the 

Calciumreactor 

is  placed  in  the  right  position  and  all  connections  are  ready,  the 

water  flow  can  be  started.  Then,  the  reactor  is  filled  up  with  water  until  water  comes  out  of  the 
outlet. Now, the circulation pump can be started and the CO

2

 can be switched on.  

 
The quantity of CO

2

 has to be adjusted the way that the pH value in the aquarium does not drop 

below pH 8.0. Within the reactor itself, the pH value should drop to pH 6.5. It is possible to control 
the pH value in the reactor, e. g. by the Aqua Medic 

ph-computer

. Next to the top (8, 9) are holes 

to put in a pH electrode. The electrode has to be pressure resistant and needs to have a standard 
thread (PG 13,5).  
 
The  backflow  of  the  calciumbicarbonate  enriched  water  into  either the aquarium or the filter tank 
should be directed to a well-flushed place in order to mix it immediately with the aquarium water. 
This avoids instabilities of the pH value. 
 

3. Maintenance 
 

The Aqua Medic 

Hydrocarbonate

 is consumed by the chemical reaction and has to be refilled from 

time  to  time.  Every  1  -  2  years,  it  should  be  replaced  completely.  Also  the  flow  rate  should  be 
checked  regularly.  It  has  to  be  re-adjusted  with  a  drop  counter.  In  case  of  polluted  water,  the 
adjustment valve in the water inflow has to be cleaned from time to time.  
 

4. Warranty 

 
Should any defect in materials or workmanship be found within 24 months of the date of purchase 
AB  Aqua  Medic  undertakes  to  repair,  or  at  our  option replace, the defective part free of charge – 
always provided the product has been installed correctly, is used for the purpose that was intended 
by  us,  is  used  in  accordance  with  the  operating  instructions  and  is  returned  to  us  carriage  paid. 
Proof  of  Purchase  is  required  by  presentation  of  the  original  invoice  or  receipt  indicating  the 
dealer’s name, the model number and date of purchase. This warranty may not apply if any model 
or production number has been altered, deleted or removed, unauthorised persons or organisations 
have  executed  repairs,  modifications  or  alterations,  or  damage  is  caused  by  accident,  misuse  or 
neglect. Please note that the product is not defective under the terms of this Warranty where the 
product, or any of its component parts, was not originally designed and / or manufactured for the 
market in which it is used. These statements do not affect your statutory rights as a customer. 
 

AB Aqua Medic GmbH

 

-

 

Gewerbepark 24 - 49143 Bissendorf/Germany 

- Technical changes reserved – 04/2017 
 

Current manuals are available for download at www.aqua-medic.de. 

 

 