background image

USER MANUAL – aquama 

® 

compact Atomizer

USER MANUAL – aquama 

® 

compact Atomizer

9

8

1

 Handle for transportation

2

 Main switch

3

 Control panel

4

 Pressure regulation

5

  ON / OFF  button

6

 Speed selector

7

 Wheels

8

 Quick coupler for hose

9

 Safety 

:

 Battery slot (option)

;

 Nozzles 

<

 Handle 

Trigger 

Trigger safety

?

 Air inlet connector

@

 Suction pipe

 Filter

 600 ml disinfectant solution tank

 Battery (option)

 Battery charger

 Compressed-air hose  

 Female quick connector 

 Male quick connector 

3.2  OPERATING MODE

1.  Make sure the gun’s 

>

 safety is engaged to prevent 

accidental trigger 

=

 activation during assembly. 

2.  Connect the male fitting 

 of the compressed 

air hose 

 to the quick connector 

8

 of the 

compressor. 

3.  Connect the female fitting 

 of the compressed air 

hose to the quick air inlet connector 

?

 of the gun. 

4.  Fill the disinfectant solution tank 

 and screw it 

onto the gun so that the suction pipe 

@

 and filter 

 are positioned inside and at the bottom of the 

tank. 

5.  Connect the power outlet of the compressor to the 

mains. The control panel will light up. If your device 
is battery operated, insert a charged battery into 
the slot 

on the back of the unit and then turn on 

your unit using the switch 

on the top left of the 

control panel.

6.  Turn on the PURE compressor with the 

5

 on/off 

button on the control panel. When the equipment is 
on, you can change the working pressure with the 

4

 pressure adjustment buttons.

The pressure gauge continuously indicates the air 
supply pressure to the gun. It is recommended to 
work in the pressure range of 0.2 to 0.8 MPa.

7.  The speed selector 

6

 allows you to choose the 

motor speed between slow (50%) or fast (99%). The 
slow speed, reduces the airflow and sound volume 
of the aquama

®

 compact Atomizer. High speed 

maximizes airflow and increases sound volume. To 
temporarily stop the aquama

®

 compact Atomizer, 

press the on/off button 

5

. When you are finished 

using the equipment, unplug the power plug from 
the mains or remove the battery.

8.  While working, hold the gun firmly by the handle 

<

 

and remove the safety 

>

.

9.  Squeeze the trigger 

=

 to atomize the disinfectant 

liquid by pointing the gun nozzles at a distance of 
1.0 to 1.5 metres towards the surfaces to be treated.

10.  If you need to refill the liquid tank, be sure to engage 

the safety 

>

 to prevent accidental triggering.

3.3  PRESSURE EQUIVALENCE  TABLE

PART 3

ASSEMBLY AND OPERATING ADVICE

3.1  AQUAMA

® 

COMPACT ATOMIZER OVERVIEW

Setting

Pressure

0.80

0.50

0 155

99

Current

Pressure

MPa

MPa

Running

Speed

%

Running

Time

Hour

PURE AIR COMPRESSOR

ATOMIZING SPRAY GUN

ACCESSORIES

1

4

5

6

3

?

<

7

8

9

:

@

;

=

>

2

MPa

Bar

PSI

0.1

1

14.5

0.2

2

29

0.3

3

43.5

0.4

4

58

0.5

5

72.5

0.6

6

87

0.7

7

101.5

0.8

8

116

0.9

9

130.5

Reviews: