USER MANUAL – aquama
®
compact Atomizer
USER MANUAL – aquama
®
compact Atomizer
9
8
1
Handle for transportation
2
Main switch
3
Control panel
4
Pressure regulation
5
ON / OFF button
6
Speed selector
7
Wheels
8
Quick coupler for hose
9
Safety
:
Battery slot (option)
;
Nozzles
<
Handle
=
Trigger
>
Trigger safety
?
Air inlet connector
@
Suction pipe
€
Filter
№
600 ml disinfectant solution tank
™
Battery (option)
∂
Battery charger
∆
Compressed-air hose
∏
Female quick connector
∑
Male quick connector
3.2 OPERATING MODE
1. Make sure the gun’s
>
safety is engaged to prevent
accidental trigger
=
activation during assembly.
2. Connect the male fitting
∑
of the compressed
air hose
∆
to the quick connector
8
of the
compressor.
3. Connect the female fitting
∏
of the compressed air
hose to the quick air inlet connector
?
of the gun.
4. Fill the disinfectant solution tank
№
and screw it
onto the gun so that the suction pipe
@
and filter
€
are positioned inside and at the bottom of the
tank.
5. Connect the power outlet of the compressor to the
mains. The control panel will light up. If your device
is battery operated, insert a charged battery into
the slot
:
on the back of the unit and then turn on
your unit using the switch
2
on the top left of the
control panel.
6. Turn on the PURE compressor with the
5
on/off
button on the control panel. When the equipment is
on, you can change the working pressure with the
4
pressure adjustment buttons.
The pressure gauge continuously indicates the air
supply pressure to the gun. It is recommended to
work in the pressure range of 0.2 to 0.8 MPa.
7. The speed selector
6
allows you to choose the
motor speed between slow (50%) or fast (99%). The
slow speed, reduces the airflow and sound volume
of the aquama
®
compact Atomizer. High speed
maximizes airflow and increases sound volume. To
temporarily stop the aquama
®
compact Atomizer,
press the on/off button
5
. When you are finished
using the equipment, unplug the power plug from
the mains or remove the battery.
8. While working, hold the gun firmly by the handle
<
and remove the safety
>
.
9. Squeeze the trigger
=
to atomize the disinfectant
liquid by pointing the gun nozzles at a distance of
1.0 to 1.5 metres towards the surfaces to be treated.
10. If you need to refill the liquid tank, be sure to engage
the safety
>
to prevent accidental triggering.
3.3 PRESSURE EQUIVALENCE TABLE
PART 3
ASSEMBLY AND OPERATING ADVICE
3.1 AQUAMA
®
COMPACT ATOMIZER OVERVIEW
Setting
Pressure
0.80
0.50
0 155
99
Current
Pressure
MPa
MPa
Running
Speed
%
Running
Time
Hour
PURE AIR COMPRESSOR
ATOMIZING SPRAY GUN
ACCESSORIES
™
∂
1
4
5
6
3
?
<
∆
∑
∏
7
8
9
:
№
@
€
;
=
>
2
MPa
Bar
PSI
0.1
1
14.5
0.2
2
29
0.3
3
43.5
0.4
4
58
0.5
5
72.5
0.6
6
87
0.7
7
101.5
0.8
8
116
0.9
9
130.5