Hydromate Control Panel Sections 

Dia 4 

Hydromate 3000   - Lighting Controls

 

Rotary screw for lux 
setting - preset at 
110/120 lux. 
(Rotate clockwise for 
darker activation) 

Reset Button 

230v Supply, L,N,E 

Valve  
Connection E,N,L 

Lighting Sw/wire connection—
in/out 

 

Connection point for 
Photocell To order 
quote ‘AQUHMPC’ 

P.I.R connections  
NB: 

3 wire Remote PIR can also 
be connected here if  
required 

Illustration shown:  
1,2,3 on (up) = 15 
minutes 

All Switches off = 
1min 

Sw1 on adds 2 mins 
Sw2 on adds 4 mins 
Sw3 on adds 8 mins 
Sw4 on adds 16 mins 

Lights on 
time delay 

Reprogramming & Care 

1. 

Should you require to increase or decrease flush frequencies, simply alter the 2-
dil switch positions. No further programming is required. 

2. 

To alter the fill time you must reset the system — stage 5. 

3. 

Wiping the fascia of the Hydromate with non-abrasive cleaners will help to keep 
the Hydromate in good condition. 

4. 

In case of a power failure, the unit’s memory will retain programmed settings.  

5. 

Unexpected  interruptions  or  pressure  differentials  with  your  water  supply  may 
cause fill times to drift over time. 

 

For further information or Technical assistance contact us on: Tel 0844 324 0844  

or Email: [email protected]  

PhotoCell (Optional) 

For areas with natural daylight. 
If using the Hydromate to power 
local lighting & you have natural 
ambient light, the PhotoCell can 
detect when the area has enough 
natural light thus overriding PIR  

Fill Button 

PIR Connection Block: 

to power lighting 
only

. Connect your  

remote PIR to this 