Hydromate Control Panel Sections
Dia 4
Hydromate 3000 - Lighting Controls
Rotary screw for lux
setting - preset at
110/120 lux.
(Rotate clockwise for
darker activation)
Reset Button
230v Supply, L,N,E
Valve
Connection E,N,L
Lighting Sw/wire connection—
in/out
Connection point for
Photocell To order
quote ‘AQUHMPC’
P.I.R connections
NB:
3 wire Remote PIR can also
be connected here if
required
Illustration shown:
1,2,3 on (up) = 15
minutes
All Switches off =
1min
Sw1 on adds 2 mins
Sw2 on adds 4 mins
Sw3 on adds 8 mins
Sw4 on adds 16 mins
Lights on
time delay
Reprogramming & Care
1.
Should you require to increase or decrease flush frequencies, simply alter the 2-
dil switch positions. No further programming is required.
2.
To alter the fill time you must reset the system — stage 5.
3.
Wiping the fascia of the Hydromate with non-abrasive cleaners will help to keep
the Hydromate in good condition.
4.
In case of a power failure, the unit’s memory will retain programmed settings.
5.
Unexpected interruptions or pressure differentials with your water supply may
cause fill times to drift over time.
For further information or Technical assistance contact us on: Tel 0844 324 0844
or Email: [email protected]
PhotoCell (Optional)
For areas with natural daylight.
If using the Hydromate to power
local lighting & you have natural
ambient light, the PhotoCell can
detect when the area has enough
natural light thus overriding PIR
Fill Button
PIR Connection Block:
to power lighting
only
. Connect your
remote PIR to this