HiQu Digital Bath
installation instructions
Page 12
The Digital processors are supplied factory set
with the flow rate at either ‘NORMAL HP’ or
‘NORMAL GRAVITY’ mode depending on which
bath system has been ordered.
STANDARD PROCESSORS ON BALANCED HP
SYSTEMS:
Standard processors fitted to balanced high pres-
sure systems may be set to ‘NORMAL HP’ or for water economy ‘ECO’ modes.
N.B. We recommend the processor is set to ‘NORMAL HP’ mode.
STANDARD PROCESSORS ON COMBINATION BOILER SYSTEMS:
For Standard Digital processors installed on combi boiler systems, for
op-
timum performance we recommend setting the flow rate to the ‘COMBI’
mode.
18
N.B. The ‘ECO’ flow rate mode should not be selected for bath systems fitted
to combination boilers.
PUMPED PROCESSORS:
Pumped processors fitted to gravity systems may be set to ‘NORMAL
GRAVITY’ or for water economy ‘ECO’ flow rate modes.
N.B. We recommend the processor is set to ‘NORMAL GRAVITY’ mode.
WHEN MAKING ANY ADJUSTMENT TO THE PROCESSOR SETTINGS
THE POWER MUST BE ISOLATED.
!
Re-instate the electricity supply to the processor and press the ‘start/stop’ but-
ton on the controller to turn the bath on.
19