6
1300 383 815
6. Technical parameter
Model
ASC 70
ASC 90
ASC 110
ASC 130
ASC 170
ASC 210
ASC 280
ASC 350S
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
6.8
9.0
11.0
13.0
17.5
20.8
27.8
35.0
COP Range
14~7.4
14~7.4
14~6.9
14.5~7.1
15.6~6.9
14.6~7.0
15.8~7.2
15.5~7.0
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
4.9
6.5
7.5
8.9
12.3
14.3
18.8
24.2
COP Range
7.2~4.4
7.3~4.7
7.3~4.6
7.5~4.9
7.7~4.9
6.9~4.9
7.8~4.9
7.5~5.0
TECHNICAL SPECIFICATIONS
Advised pool volume (m
3
)
15~30
20~45
30~55
35~65
40~80
50~95
60~120
85~160
Operating air temperature (
℃
)
-10
℃
~43
℃
Power supply
230V 1PH
400V 3ph
Rated input power (kW)
0.14~1.12
0.19~1.38
0.22~1.63
0.26~1.82
0.32~2.51
0.38~2.92
0.5~3.84
0.65~4.84
Rated input current (A)
0.63~4.83
0.83~5.98
0.96~7.09
1.13~7.83
1.39~10.9
1.65~12.7
2.17~16.7
0.95~7.01
Power cord (mm²
)
3X1.5
3X2.5
3X2.5
3X2.5
3X4
3X4
3X6
5X2.5
Sound level at 10m dB(A)
16.5~26.0
16.8~26.1
16.6~27.9
20.1~28.7
21.1~31.8
18.9~32.2
21.5~32.9
20.6~32.6
Advised water flux (m³/h)
2~4
2~4
3~5
4~6
6~8
8~10
10~12
12~18
Water connection (mm)
48.3
Remarks:
This heat pump is able to perform normal within air temp -10
℃~
+43
℃
, efficiency will not be guaranteed
out of this range. Please take into consideration that the pool heat pump performance and parameters
are different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
Summary of Contents for ASC 110
Page 1: ...Mar 2021 USER MANUAL ...
Page 24: ...22 hello aquaheataustralia com au 1300 383 815 J Wi Fi Operation ...
Page 25: ...23 hello aquaheataustralia com au 1300 383 815 ...
Page 26: ...24 hello aquaheataustralia com au 1300 383 815 ...
Page 27: ...25 hello aquaheataustralia com au 1300 383 815 ...
Page 28: ...26 hello aquaheataustralia com au 1300 383 815 ...
Page 29: ...27 hello aquaheataustralia com au 1300 383 815 ...