11
4. References for protecting devices and cable specification
※
Above data is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be
increased. The signal cable can be extended to 50m maximally.
E. Operation Guidance
1. Key function
Symbol
1. Power On/Off
2. Wi-Fi setting
1. Lock/Unlock Screen
2. Heating mode (18-40°C)
3. Cooling mode (12-30°C)
4. Auto mode (12-40°C)
1. Boost
2. Silence
Temperature Setting
Attention:
i.
The controller has power-down memory function.
ii.
The buttons will turn dark when it’s locked.
2. Operation instruction
a. Screen Lock
1)
Press “
” for 3 seconds to lock or unlock the screen
2) Automatic Lock Period: 30 seconds if no operation
b. Power On
Press “
” for 3 seconds to unlock screen, then press “
” to power on machine.
MODEL
AS70
AS90
AS110
AS130
AS170
AS210
AS280
AS280S
Breaker
Rated Current (A)
9
10.5
12
14.5
18
21
24
9
Rated Residual
Action Current
(mA)
30
30
30
30
30
30
30
30
Fuse (A)
9
10.5
12
14.5
18
21
24
9
Power Cord (mm
2
)
3x1.5
3 x 2.5
3 x 2.5
3 x 2.5
3 x 4
3 x 4
3 x 6
5 x 2.5
Signal cable (mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
Summary of Contents for AS110
Page 1: ...aquaheat INVERTER POOL HEAT PUMP USER MANUAL ...
Page 2: ......
Page 24: ...21 J Wi Fi Operation ...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ...AQ00ASC R32 P5 ...