7. EXTERNAL CONTROL

External  control  can  be  enabled  via  following  contacts.  Pressing  on/off  can  stop  the  pump 
even if working via an external controller. 

 
a. 

Digital Input

To enable external speed control, connect one of the digits from Di1/2/3/4 to 

COM. See schematic as belo

b. 

Relay Output:

 Connect terminal L & N to enable external control. An additional on

necessary while bearing power

 

Control system digital input

 

. EXTERNAL CONTROL

Not included in standard model

External  control  can  be  enabled  via  following  contacts.  Pressing  on/off  can  stop  the  pump 
even if working via an external controller.   

To enable external speed control, connect one of the digits from Di1/2/3/4 to 

COM. See schematic as below: 

 

Connect terminal L & N to enable external control. An additional on

necessary while bearing power is less than 500W (2.5A). See schematic as below:

 

system digital input

 

Relay external control output

Not included in standard model

 

External  control  can  be  enabled  via  following  contacts.  Pressing  on/off  can  stop  the  pump 

 

To enable external speed control, connect one of the digits from Di1/2/3/4 to 

 

Connect terminal L & N to enable external control. An additional on-off is 

. See schematic as below: 

 

Relay external control output

 

Summary of Contents for XFIow INVERSilence GFVS09N

Page 1: ......

Page 2: ...SPECIFICATIONS 1 3 OVERALL DIMENSION 2 4 INSTALLATION 2 5 SETTING OPERATION 4 6 WIRING CONNECTION 6 7 EXTERNAL CONTROL Not included in standard model 7 8 TROUBLE SHOOTING 8 9 ERROR CODE 9 10 MAINTENA...

Page 3: ...n if you cannot verify that the This pump is for use with permanent installed in ground or above ground swimming pools and may also be used with hot tubs and spas if so marked Do not use with above gr...

Page 4: ...It is recommended to place pump indoor or in the shade 3 Do NOT install pump in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling 4 2 Piping 1...

Page 5: ...ion line diameter must equal or be larger than the discharge line diameter Please note the inlet and outlet for GFVS15N GFVS19N is 63mm while for GFVS09N GFVS11N the inlet could be 50 63mm outlet is 5...

Page 6: ...o Timer mode Capacity 40 100 5 2 Capacity Setting Note The inverter module can be operated manually or automatically at regular intervals The system automatically saves the 4 latest valid settings NO...

Page 7: ...conds 5 4 Parameter Setting Under OFF mode hold for 3 second to enter parameter settings Parameter Description Default Setting Setting Range 1 Di2 100 40 100 by 5 increments 2 Di3 80 3 Di4 40 1 enter...

Page 8: ...h 50Hz 6 WIRING CONNECTION All electrical wiring MUST conform with applicable National Electrical Safety Code NESC and National Electric Code NEC Please refer to the below schematic for information on...

Page 9: ...contacts Pressing on off can stop the pump even if working via an external controller To enable external speed control connect one of the digits from Di1 2 3 4 to COM See schematic as below Connect t...

Page 10: ...sket loaded with debris Suction side clogged Pump is not primed Air entering suction piping Basket full of debris Inadequate water level in pool Air leak in suction piping cavitations caused by restri...

Page 11: ...trapped refuse from the basket Hose out with water if necessary NOTE Do not knock the plastic basket on a hard surface as it will cause damage 5 Check the strainer basket for cracks replace the basket...

Page 12: ...uences resulting from inappropriate incorrect installation or mismatching of the product to pool pumps that are not compatible 12 WEEE LEGISLATION When disposing the product please hand it over to a d...

Reviews: