background image

 

Unscrew

 

the

 

hose

 

tail;

 

open

 

the

 

upper

 

cover;

 

loosen

 

the

 

screws

 

of

 

the

 

back;

 

and

 

then

 

take

 

out

 

the

 

UVC

 

clarifying

 

unit

 

(c).

 

 

 

Take

 

out

 

the

 

filter

 

materials

 

respectively,

 

and

 

rinse

 

with

 

clean

 

pond

 

water

 

(d)

 

and

 

discard

 

the

 

dirty

 

water.

 

 

Unscrew

 

the

 

1

 

inch

 

unit

 

of

 

the

 

outlet,

 

drain

 

the

 

sewage

 

from

 

the

 

main

 

housing

 

(e).

 

 
 
 
 

 
 
 
 

 

Slide

 

the

 

red

 

switch

 

lock

 

to

 

unlock

 

the

 

unit

 

head

 

and

 

housing

 

(f).

 

 

Turn

 

the

 

unit

 

head

 

counter

clockwise

 

against

 

the

 

stop

 

(b),

 

then

 

carefully

 

pull

 

it

 

out

 

of

 

the

 

housing.

  

 

Loosen

 

the

 

screw

 

(h).

 

Screw

 

off

 

the

 

union

 

nut,

 

pull

 

off

 

the

 

quartz

 

glass

 

including

 

the

 

O

 

ring

 

by

 

a

 

slight

 

rotary

 

movement

 

(i).

 

 

Clean

 

the

 

quartz

 

glass

 

outer

 

face

 

with

 

a

 

moist

 

cloth

 

carefully

 

and

 

check

 

for

 

damage.

 

 

When

 

replacing

 

the

 

UVC

 

lamp,

 

remove

 

the

 

quartz

 

glass.

 

(Fig.

 

E)

 

 

Replace

 

the

 

UVC

 

lamp.

 

Only

 

use

 

lamps

 

the

 

designation

 

and

 

rating

 

of

 

which

 

match

 

the

 

information

 

on

 

the

 

type

 

plate.

  

  

Important

 

  

Switch

 

the

 

pump

 

of

 

first,

 

then

 

the

 

UVC

 

clarifying

 

unit.

 

Do

 

not

 

operate

 

the

 

unit

 

without

 

water

 

flowing

 

through.

  

The

 

unit

 

switches

 

on

 

automatically

 

when

 

power

 

connection

 

is

 

established.

 

After

 

a

 

new

 

installation,

 

the

 

unit

 

only

 

reaches

 

its

 

fully

 

biological

 

cleaning

 

effect

 

after

 

a

 

few

 

weeks.

 

The

 

full

 

effect

 

on

 

bacteria

 

is

 

only

 

reached

 

as

 

from

 

a

 

water

 

temperature

 

of

 

+10°C.

 

Switching

 

on:

 

Connect

 

power

 

plug

 

to

 

socket.

 

After

 

switching

 

on

 

the

 

UVC

 

clarifying

 

unit,

 

check

 

whether

 

or

 

not

 

the

 

UVC

 

lamp

 

is

 

lit

 

blue

 

(Fig.

 

A)

 

through

 

the

 

control

 

window

 

on

 

the

 

upper

 

cover

 

(with

 

UVC).

 

Check

 

all

 

connections

 

for

 

leaks.

  

Switching

 

off:

 

Disconnect

 

the

 

power

 

plug.

 

 

Disposal

 

Do

 

not

 

dispose

 

of

 

this

 

unit

 

with

 

domestic

 

waste!

  

 
 
 

 

Remedy

 

of

 

faults

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Guarantee

 

We

 

provide

 

a

 

guarantee

 

of

 

2

 

years

 

from

 

the

 

date

 

of

 

purchase

 

on

 

the

 

Aquagarden

 

BIOlogic

 

Gravity

 

Filter.

 

This

 

guarantee

 

does

 

not

 

cover

 

parts

 

subject

 

to

 

wear

 

and

 

tear,

 

such

 

as

 

batteries,

 

impellers,

 

lamps,

 

ceramic

 

discs

 

and

 

O

 

rings,

 

or

 

any

 

damages

 

that

 

are

 

a

 

result

 

of

 

misuse,

 

tampering

 

(including

 

damage

 

and

 

alteration

 

of

 

the

 

cable),

 

negligence,

 

damage

 

and

 

technical

 

modification.

 

We

 

reserve

 

the

 

right

 

to

 

repair

 

or

 

replace

 

the

 

unit.

 

No

 

repairs

 

or

 

replacement

 

will

 

be

 

undertaken

 

for

 

products

 

that

 

have

 

not

 

been

 

properly

 

maintained.

 

The

 

guarantee

 

will

 

be

 

honoured

 

only

 

if

 

the

 

product

 

is

 

returned

 

to

 

your

 

dealer

 

or

 

Aquagarden

 

(freight

 

pre

paid)

 

compete

 

with

 

your

 

receipt.

 

Product

 

will

 

deteriorate

 

with

 

prolonged

 

exposure

 

to

 

sunlight

 

and

 

fading

 

of

 

the

 

product

 

is

 

not

 

covered

 

by

 

the

 

guarantee.

  

The

 

refund

 

of

 

costs

 

for

 

removal

 

or

 

installation,

 

onsite

 

inspection,

 

check

 

and

 

claims

 

for

 

lost

 

profit

 

caused

 

by

 

the

 

unit

 

or

 

its

 

use

 

are

 

exempted

 

from

 

the

 

guarantee.

  

Our

 

goods

 

come

 

with

 

guarantees

 

that

 

cannot

 

be

 

excluded

 

under

 

the

 

Australian

 

Consumer

 

Law.

 

You

 

are

 

entitled

 

to

 

a

 

replacement

 

or

 

refund

 

for

 

a

 

major

 

failure

 

and

 

compensation

 

for

 

any

 

other

 

reasonably

 

foreseeable

 

loss

 

or

 

damage.

 

You

 

are

 

also

 

entitled

 

to

 

have

 

the

 

goods

 

repaired

 

or

 

replaced

 

if

 

the

 

goods

 

fail

 

to

 

be

 

of

 

acceptable

 

quality

 

and

 

the

 

failure

 

does

 

not

 

amount

 

to

 

a

 

major

 

failure.

 

 

The

 

benefits

 

to

 

you

 

given

 

by

 

the

 

warranty

 

are

 

in

 

addition

 

to

 

other

 

rights

 

and

 

remedies

 

of

 

the

 

consumer

 

under

 

a

 

law

 

in

 

relation

 

to

 

the

 

goods

 

and

 

services

 

to

 

which

 

the

 

warranty

 

relates.

  

 

In

 

the

 

advent

 

of

 

a

 

warranty

 

claim

 

please

 

contact

 

the

 

place

 

of

 

purchase

 

or

 

alternatively

 

ring

 

us

 

on

 

1800

 

222

 

010

 

for

 

details

 

on

 

returning

 

the

 

product.

 

 

Reviews: