Page 1: ...W ARNIN G XE HRSM MODEL o HRSM 2000 o HRSM 2001 3ph o HRSM 1500 Read Understand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL Listed Motors Components NOTICE ...

Page 2: ...ATH OR SERIOUS INJURY WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY NOTICE INDICATES IMPORTANT INFORMATION THAT IF NOT FOLLOWED MAY CAUSE DAMAGE TO EQUIPMENT TABLE OF CONTENTS WARNING CAUTION NOTICE Notes DESCRIPTION Aqua...

Page 3: ...United States National Electrical Codes NEC and Occupational Safety and Health Act OSHA 5 Only persons well acquainted with these rules of safe operation should be allowed to use the atomizer 6 Keep visitors away and NEVER allow children in the work area 7 Use of an extension cord for the HRSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified ...

Page 4: ...SE ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 14 AWG 12 AWG 230 16 AWG 14 AWG Fig 12 ELECTRICAL GROUND FAULT RECEPTACLES ARE RECOMMENDED AND MAY BE REQUIRED BY LOCAL AND OR NATIONAL CODE WARNING USE OF AN EXTENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE Grounded and suitable for outdoor use UNIT PREPARATION Visually check to make sure that the critically...

Page 5: ...n pivoting fogging head with 15º intervals up to 45º Propelling the fog upward allows more time for the particles to evaporate keeping floor areas drier When making an adjustment balance the weight of the fogging head off of the pin for easy removal See Fig 4 Flow Control Strainer Pivot Fig 4 Adjustment Pin OFF ON INSTALLATION A Automated Operation Connect the unit s power cord to a power supply c...

Page 6: ...malities such as the blades rubbing against the venturi Make re adjustments if necessary Evaluate fog quality adjusting the output by using the flow control valve See Fig 3 After starting it generally takes several seconds for the liquid to reach the atomizing fan BEFORE TESTING FAN MAKE SURE ALL OBJECTS ARE OUT OF THE ROTATION PATH OF THE FAN BLADES HIGH SPEED WARNING KEEP HANDS CLEAR MAKE SURE G...

Page 7: ...n the handle is down and closed when up If the valve is open and there is still no fog the pump may need to be primed In rare cases the pump may retain an air bubble To prime the pump remove the inline strainer cap Part 71 and turn the system ON for a few seconds Replace cap and try operating unit again B If pump is receiving electricity but there is no fog check for sediment in the pump s intake ...

Page 8: ... circuit If the breaker continues to trip the motor is probably in need of repair Consult an electrician for evaluation 9 Fan and or Motor Vibration A If the fan unit begins vibrating severely first be sure the blade assembly is fully engaged and securely tightened on the motor shaft Next inspect the blade assembly particularly the ends of the blades Look for wear or cracks replace as necessary Lo...

Page 9: ...ner 1 41 10 24 x 1 2 phillips RH SST 4 42 10 24 nylon stop nut SST 4 43 11 16 x 1 1 4 flat washer SST 1 44 Drain tubing 3 45 Liquid tight cord fitting 2 46 Key 1 47 Tree clip 3 51 Right aluminum angle bracket 1 52 1 4 20 x 3 4 HH bolt SST 4 54 1 4 20 x 3 8 button head cap screw 6 55 Left aluminum angle bracket 1 56 5 16 18 x 3 4 HH bolt SST 10 57 5 16 lock washer SST 8 58 5 16 flat washer SST 8 11...

Page 10: ...view of motor Side of top pivot plate Rear of Housing Power supply in from on off switch Power supply out to pump 5 8 13 14 15 16 52 51 55 117 54 20 344 46 58 56 45 45 43 47 8 39 44 32 58 57 56 57 116 349 403 391 392 56 394 395 32 479 ...

Page 11: ... 65 59 372 76 82 85 86 86 92 89 88 87 351 60 61 84 109 45 110 71 69 75 72 72 65 65 143 143 65 65 84 45 198 67 65 Tank s Wall Inside Tank 93 94 95 96 43 Three Phase Components Single Phase Components HRSM TANK EXPLODED VIEW 487 SJO 14 4 ...

Page 12: ...itch cover 1 86 6 32 x 1 2 oval slotted screw 6 87 Electrical switch box 3 phase 1 88 Switch 3 phase 1 89 Spacer plate 3 phase 1 92 Switch cover 3 phase 1 93 Hose connector gasket 1 94 Hose connector 1 95 1 2 M x 3 8 F reducer bushing 1 96 Gasket 2 97 Float valve 1 98 Stem 1 99 Float 1 100 Pump HRSM 115 volt 60hz 1 101 Pump HRSM 230 volt 50hz 1 106 Pump support plate 1 108 8 x 5 8 self tapping phi...

Page 13: ...pray oil around the shaft where it exits the motor body Lubricate motor once a season or whenever squealing occurs 4 Inspect Blade Assembly Clean the blade assembly about once a year especially if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up from the blades and any debris from blade passageways While cleaning inspect for irregularities or hairl...

Page 14: ...dent lack of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURING INC S LIABILITY FOR DEATH INJURIES TO PERSONS OR PROP ERTY OR FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE USE OF OUR EQUIPMENT IS EXPRESSLY DISCLAIMED JAYBIRD MANUFACTURING INC ...