Page - 19
1.5 Electrical
1.5.a Electrical Requirements
DANGER
Failure to heed the following will result in injury or death.
l
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
WARNING
Failure to heed the following may result in injury or death.
l
The information contained in this section is intended for use by qualified electricians familiar with electrical
service-industry safety standards and methods.
l
Locate the equipment disconnect as near to the heat pump as possible. Always satisfy applicable codes and
standards.
l
Never mount power-disconnects directly to the heat pump.
l
In sizing power wiring, be especially aware of up-sizing requirements necessary due to wiring distances. Always
satisfy applicable codes and standards.
l
AquaCal
®
heat pumps are designed to use copper conductors, only. Do not use aluminum wire.
l
If multiple heat pumps are on-site, confirm that the multiple heat pump configuration has been utilized.
Connecting Multiple Heat Pumps (Primary / Secondary)
" on page 41. This will prevent multiple heat pumps
attempting to start at the same time, causing an excessive power drop at start-up.
Electrical Standards
Standards
Title
NFPA 70, Nat'l Elec.
Code 2017
The electrical installation must conform to the current
version of the National Electric Code (NEC), and all
applicable local and state codes
IEC 60335-1
Household and similar electrical appliances - Safety -
General Requirements
IEC 60335-2
Household and similar electrical appliances - Safety –
Particular requirements for electrical heat pumps, air-
conditioners, and dehumidifiers
UL 1995 & CSA C22.2
No. 236-15
Standard for Safety - Heating and cooling equipment
Table 3 - Standards
Grounding and Bonding
Follow local code requirements for proper grounding and bonding of heat pump equipment.
l
A bonding lug has been provided on the lower left hand corner of the plumbing access panel.
1
-
Ins
ta
lla
tion
Summary of Contents for AutoPilot SP05
Page 2: ......
Page 9: ...Page 5 Water Source Top View Water Source Side View 1 Installation...
Page 10: ...Page 6 1 3 Dimensions Water Source WS03 WS05 Water Source WS10 1 Installation...
Page 31: ...Page 27 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 32: ...Page 28 1 Installation...
Page 36: ...Page 32 1 Installation...
Page 39: ...Page 35 1 Installation...
Page 43: ...Page 39 1 Installation...
Page 44: ...Page 40 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 48: ...Page 44 1 Installation...
Page 50: ...Page 46 1 Installation...
Page 53: ...Page 49 1 Installation...
Page 56: ...Page 52 1 Installation...
Page 58: ...Page 54 1 Installation...
Page 61: ...Page 57 1 Installation...
Page 63: ...Page 59 1 Installation...
Page 83: ...Page 79 l Follow all National Electric Codes NEC and or State and Local guidelines 3 Appendix...
Page 88: ......