background image

 

 

TOOLS AND PARTS REQUIRED FOR INSTALLATION

 

 

Your 

Pool Pilot® Professional 

system will include an installation kit 

comprising of the  following items:

 

Description 

Qty

 

Strainer clear bowl with 20 mesh 

PVC ball valve Sch. 40 

PVC male adaptor Sch. 40 

PVC nipple SCH 80 

PVC bushing Threaded 

PVC union S EPDM w/o 
O-ring Sch. 80 threaded 

Akenstrut clamps 

Polypropylene valve, speed fit 

Elbow street 90, SCH 80 

Salt test strips 

 

Additionally you will need the following items, not included, to complete 
the installation:

 

 

• 

Polypropylene tubing 

• 

Flex PVC tubing 

• 

Wall anchors 

• 

Disconnect box, fuse box, conduit, wiring and related material to supply 220v to systems 
(220v systems only) 

 
 

The following tools will be required to complete the installation:

 

 

Power Tools 

Drill Bits

 

 

Drill 

Hole saw 

Hammer Drill 

Paddle bit 
Steel bit drill set 
Mason bit 

 

Hand Tools 

Taps

 

 

Set of sockets 

2.5cm 

Hammer 

0.9cm 

Screw Drivers – Flat & Phillips 
Wire Strippers 
PVC Cutters 

Hand Tools cont..

 

24” (60 cm) Level 

Tape Measure 

Slip joint pliers 

Teflon Tape 

Crescent wrench 

Allen Wrenches 
True RMS Clamp Meter 
Wire Cutters 

Summary of Contents for Pool Pilot PROB28

Page 1: ...ST CONTROL PRODUCTS ACT This electrode must only be used on this model of chlorine generating device READ THE LABEL AND REFER TO OWNERS MANUAL OF THE Pool Pilot Professional Model PROB28 BEFORE USING...

Page 2: ...USER S GUIDE MODEL PROB28...

Page 3: ...YOUR WATER BEFORE INSTALLATION 8 9 SALT CHART FOR CORRECT MAINTENANCE 10 TOOLS AND PARTS REQUIRED FOR INSTALLATION 11 PLUMBING YOUR SYSTEM 12 13 ELECTRICAL SPECIFICATIONS 14 ELECTRICAL SPECIFICATIONS...

Page 4: ...st be maintained KEEP OUT OF REACH OF CHILDREN READ THE LABEL AND OPERATING MANUAL BEFORE USING REGISTRATION NO 33688 PEST CONTROL PRODUCT ACT WARNING Operating the Pool Pilot Professional Saline Chlo...

Page 5: ...RODUCTION AquaCal AutoPilot Inc 2737 24th St North St Petersburg Florida U S A 33713 1 727 823 5642 Patent US 6821398B2 EPA Est 082229 GA 001 NSF 50 UL 1081 listed Congratulations on purchasing your n...

Page 6: ...titanium electrodes will not be honored if the system is operated in water temperatures lower than 15 degrees C AquaCal AutoPilot Inc warranties of the titanium electrodes will not be honored if the...

Page 7: ...onal system never operates when the pumps are off All boxes on your Pool Pilot Professional system contain high voltage components Never open any box while power is on WARNING Heavy pool and or spa us...

Page 8: ...ed from destruction by sunlight by addition of stabilizer cyanuric acid NOTE FOR USE ON SPAS For proper sanitation spas must be completely drained periodically The number of days between COMPLETE DRAI...

Page 9: ...ously until the salt has all dissolved You must never leave large amounts of salt on the surface of the pool as this may cause damage to the pool surface When you add the initial load of salt you will...

Page 10: ...e accurate readings failure to calibrate the equipment will result in inaccurate readings How to Calculate volume of a pool For a rectangular shaped pool Length m x Width m x Average Depth m x 1000 Li...

Page 11: ...180 200 4400 6 60 120 180 240 300 360 420 480 540 600 4000 10 100 200 300 400 500 600 700 800 900 1000 3800 12 120 240 360 480 600 720 840 960 1080 1200 3500 15 150 300 450 600 750 900 1050 1200 1350...

Page 12: ...nally you will need the following items not included to complete the installation Polypropylene tubing Flex PVC tubing Wall anchors Disconnect box fuse box conduit wiring and related material to suppl...

Page 13: ...rine production and ultimately reducing flow to the point that the flow switch de activates the system 3 If you elect to use the bypass plumbing method 2 you will need to purchase a butterfly valve ba...

Page 14: ...PRESENT THE OUTLET LINE THAT FEEDS THE CONTROLLER PROBES COULD BE CONNECTED TO THE RECTIFIER BYPASS MANIFOLD PLUMBING METHOD 2 NOTES THE RECTIFIER COOLING LINES MUST BE CONNECTED FROM THE SUCTION SID...

Page 15: ...y switch then into the Pool Pilot Professional main power box 1 As above the cord labeled ORP must be plugged into a controller or a 120v outlet Your Pool Pilot Professional system must be wired to th...

Page 16: ...you are running your system manually you will need to find the point at which you keep a satisfactory level of chlorine in the water It may take several days to find this point If your Pool Pilot Pro...

Page 17: ...1 you will notice the amperage needle of the gauge on box 3 increases or decreases Higher amperage higher chlorine production Normal operating amps and volts for this model device are PROB28 125amps...

Page 18: ...e most critical part of the system You will notice that over time a white substance calcium minerals will build up on the plates especially at the top of the cell This buildup needs to be cleaned by r...

Page 19: ......