background image

Using your 

UA 2 aquaBUBBLER

At times the water flow may fluctuate depending 

on your local water supply pressure. Re-adjusting 

is simple using a 6mm flat head screw driver.

Read water meter via slot

Adjusting water flow

Adjust Water Flow

Dome Head Bolt 

One hundred twenty three thousand  

four hundred and fifty six litres

Trouble Shooting

Water Meter Slot

Water flow will need adjusting 1-2 days after installation

What to do if the UA 2 aquaBUBBLER becomes blocked? 

You will need to unblock the S-Trap. 

This means removing the stainless steel (S/S) dish.

Use the security key provided unfasten the four security screws. 

Remove S/S dish. 

Remove the S-Trap and unblock it. 

Reattach the S-Trap. 

Reattach the S/S dish and re-fasten the security screws.

What to do if the water bottle pod becomes blocked?

Use the security key provided. 

Unfasten the security screws. 

Remove the S/S mesh. 

Unblock the pod. 

What to do if the tap leaks?

Remove the S/S dish. 

Turn off the isolation valve. 

Disconnect the flexi hose. 

Undo the hex connector at the base of 

the tap. 

Remove the spring. 

Use an 8mm flat head screw driver to 

remove the spindle. 

Wash spindle or replace broken o-ring. 

Don't forget to lube top o-ring.

Re-assemble tap.

 

(For better

 purchase, do not remove 

tap from S/S dish or from body of 

aquaBUBBLER.)  

Ensure the water-bottle 

pod is full of water before 

using the UA 2 

aquaBUBBLER

(The water meter is an optional extra.)

>

 

>

 

>

  IMPORTANT 

We highly recommend regular cleaning, to ensure your UA 2 aquaBUBBLER is hygienic and attractive to drink from.

www.aquabubbler.com.au

0800 213 774

1300 213 774

www.aquabubbler.co.nz

 Using & Caring for Your Universal 2 aquaBUBBLER

Reviews: