background image

16

Residential Steambath       

warranty

Limited Lifetime Warranty

aquasteam

 extends to the original consumer purchaser of a 

aquasteam. 

RESIDENTIAL STEAMBATH GENERATOR 

(aquasteam Generator), installed in the United States or 
Canada (excluding controls and accessories), a warranty that 
such 

aquasteam

 Generator is free from defects in materials 

and workmanship. aquasteam will repair or replace at its 
option a  Generator if it fails to conform to this warranty.

Limited One Year Warranty for Controls and Accessories

aquasteam

 extends to the original consumer purchaser of a 

Control or Accessory for a 

aquasteam

 RESIDENTIAL steambath 

generator which is installed in the United
States or Canada, a one year limited warranty that such 
aquasteam control and accessory is free from defects in 
materials and workmanship. 

aquasteam

 still repair or replace 

at its option a 

aquasteam

 control or accessory if it fails to 

conform to this warranty.

Terms, Conditions, and Exclusions

This warranty is non-transferable. All warranties for a 

aquasteam

 Generator and 

aquasteam

 control or accessory 

(collectively, 

aquasteam

Products) apply only to the original 

consumer purchaser
This warranty does not apply to a 

aquasteam

 Product which is 

sold “as is” or in a damaged condition or is installed for use in 
other than a residential steambathing application.
This warranty does not apply to repairs or replacement 
necessitated by any cause beyond the control of aquasteam-
including, but not limited to, any malfunction, defect, or 
failure caused by or resulting from unauthorized service or 
parts, improper maintenance, and/or problems arising due to 
local water conditions, operation contrary to furnished 
instructions, damages occurring during shipment, transit, 
storage, or handling, or arising from modification or repair by 
any person not authorized by aquasteam, abuse, misuse, 
neglect, accident, incorrect power line voltage, fire, freezing, 
flood, or other Acts of God.
AQUASTEAM  PRODUCTS MUST BE INSTALLED, OPERATED, 
AND MAINTAINED IN ACCORDANCEWITH aquasteam’S 
INSTRUCTIONS. FAILURE TO FOLLOWTHE INSTALLATION, 
OPERATION,OR MAINTENANCE PROCEDURES OR USE OF 
UNAUTHORIZED PARTS AUTOMATICALLY VOIDS THIS LIMITED 
WARRANTY. The original consumer purchaser is responsible 
for the suitability of the 

aquasteam

 Product for the applica-

tion intended by such original consumer  purchaser. This 
limited warranty does not cover any costs incurred for the 
removal or reinstallation of the 

aquasteam 

Product. 

THIS WARRANTY DOES NOT APPLY TO AQUASTEAM PROD-
UCTS WHICH ARE USED FOR ANY NON-RESIDENTIAL OR 
COMMERCIAL PURPOSE. THE FOREGOING IS IN LIEU OF ALL 
EXPRESS OR IMPLIED WARRANTIES AND AQUASTEAM DOES 
NOT ASSUME OR AUTHORIZE ANY PARTY TO ASSUME FOR IT 
ANY OTHER OBLIGATION OR LIABILITY. THERE ARE NOWAR-
RANTIES WHICH EXTEND BEYOND THE DESCRIPTION 
CONTAINED HEREIN AND SPECIFICALLY LIABILITY FOR ANY 
BREACH OF ANY IMPLIED WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PURPOSE IS EXCLUDED. THE DURATION OF 
ANY WARRANTIES WHICH MAY BE IMPLIED BY LAW 
OTWITHSTANDING  THE PREVIOUS SENTENCE (INCLUDING 
THE WARRANTIES OF MERCHANTABILITY AND FITNESS) 
SHALL IN NO EVENT EXCEED ONE YEAR. IN NO EVENT SHALL 
AQUASTEAM BE LIABLE FOR SPECIAL, INCIDENTAL, OR 
CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR 
USE OF ANY AQUASTEAM    PRODUCT; OR FOR ANY DELAY IN 
THE PERFORMANCE OF ITS OBLIGATIONS UNDER THISWAR-
RANTY DUE TO CAUSES BEYOND ITS CONTROL. SOME STATES 
DO NOT ALLOW LIMITATIONS ON HOW LONG ANIMPLIED 
WARRANTY LASTS AND/OR DO NOT ALLOW THE EXCLUSION 
OR LIMITATION OF CONSEQUENTIAL DAMAGES; SO THE 
ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO 
YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. 
YOU MAY HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO 
STATE.

Summary of Contents for Aquasteam ABSC02782

Page 1: ...Installation Operation Maintenance Manual Residential Steambath Generator Systems Leave with Homeowner Leave with Homeowner aquabrass com ...

Page 2: ...rain Safety Valve Generator Dimensions 6 Electrical Specifications 7 Wiring Diagrams 7 Field Power Wiring 8 Start up Maintenance 8 Optional Automatic Drain System 9 _____________________________________________________ Aquasteam In Shower Controls Installing the In Shower Control 12 13 Installing the Remote Temperature Probe 10 11 Operation of In Shower Control 14 Care Tips 14 Replacement Parts Di...

Page 3: ..._________________ MODEL NO ______________________________ SERIAL NO MODELS _____________________________________ _____________________________________ _____________________________________ warning caution M A DE IN U SA LISTED STEAM B ATH GENERATOR 777D REDUCE THE RISK OF OVERHEATING AND SCALDING 1 EXIT IMMEDIATELY IF UNCOMFORTABLE DIZZY OR SLEEPY STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CA...

Page 4: ...Room Model No KW Vol ft3 cu meters Compare the Total Cubic Feet required h to the Specification Chart below and select the appropriate model Note To convert cubic feet ot cubic meters divide cubic feet by 35 3 Example Total cubic feet required is 155 Divide by 35 3 to obtain 4 39 m3 Select model ABSC02787 IMPORTANT The guideline for selecting the steambath generator is a recommendation only Becaus...

Page 5: ...rovide suitable anti skid strips or equivalent to prevent user slipping and injury 4 Walls and ceilings must be constructed of water resistant non corrosive surface such as tile marble molded acrylic or other non porous material The ceiling should be sloped to prevent dripping of condensate If acrylic fiberglass or other non heat resistant materials are used as part of the steamroom enclosure see ...

Page 6: ...nd top of the steam generator or as required for servicing See page 6 10 Provide unions as required to facilitate installation and disconnection of piping 11 IMPORTANT Steam line safety valve drain valve plumbing and steamheads become hot during operation and remain hot after shutdown for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and st...

Page 7: ... steam Steam Head 1 2 NPT INSTALLER Because the steam head and direct steam emissions are very hot locate the steam head where incidental contact by bather with the steam head or direct steam emission cannot occur 1 Locate steam head 6 12 inches 15 30 cm above floor except for Tub shower enclosures install 6 in 15 cm above tub top edge For enclosures with acrylic or other non heat resistant floori...

Page 8: ...8 251 ___________________________________ C 11 7 8 302 12 1 2 310 ___________________________________ D 14 3 4 375 18 3 4 466 ___________________________________ E 1 3 4 45 1 3 4 45 ___________________________________ F 1 7 8 48 2 3 8 60 ___________________________________ G 5 1 8 130 4 102 ________________ __ _________________ H 5 127 6 152 ___________________________________ I 6 3 4 171 7 7 8 20...

Page 9: ...el No Volume ft3 m2 KW phase Amperes AWG mm2 _______________________________________________________________________________________ ABSC02787 225 6 37 7 5 240 1 32 8 10 _______________________________________________________________________ ABSC02789 360 10 19 9 0 240 1 38 8 10 __________________________________________________________________________ _____________________________________________...

Page 10: ...eam will shut offautomatically when control timer reaches zero To shut steam offmanually turn control OFF To clear steam from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for twenty seconds and try again Maintenance steambath generators require little maintenance Other than periodic d...

Page 11: ...tallation Instructions 1 Disconnect all power supplied to the unit 2 Plumbing to be performed by a qualified licensed plumber and shall be in accordance with applicable National and Local Codes Unit drains by gravity A drain line that is lower than the Automatic Drain assembly must be available The Automatic Drain valve outlet is threaded 1 2 NPT Check plumbing code for receptor trap and vent requ...

Page 12: ...E PROBE DO NOT LOCATE THE PROBE NEAR OR ABOVE THE STEAMHEAD ASTHIS MAY CAUSE DIRECT STEAM EMISSION TO INTERFERE WITH STEAMROOM TEMPERATURE REGULATION 2 Drill a 5 16 inch 8 mm diameter hole in the wall as shown in Diagram 1 Do not oversize or undersize the hole Clean area thoroughly 3 Remove the knock out from the steam generator jacket as shown in Diagram 2 4 Insert the remote temperature probe ca...

Page 13: ...mm of the bulb exposed as shown below Insure a minimum of 1 4 in 6mm of the temperature bulb is exposed to the air Failure to do so may result in an inoperative control and a hazardous condi tion The exposed area of the temperature bulb must be free of silicone or any materials that prevent direct exposure to the steam room air Failure to do so may interfere with the ability to sense temperature a...

Page 14: ...he instructions Proceed with installa tion and verification of proper control function IMPORTANT Turn power to the steam generator OFF before installing the control Failure to turn the power offwill result in an inoperable control Step 4 Remove discard peel offpaper to expose adhesive liner as shown Step 5 Run a bead of silicone provided as shown around the edge of the hole IMPORTANT Do not apply ...

Page 15: ...Connection of Aquasteam Control TemperatureSensor Temp Probe Main Control Note Valve should be closed when automatic drain is not installed aquabrass com Residential Steambath Generator Systems 13 ...

Page 16: ...eys will increase or decrease the current temperature setting The new and desired temperature setting Set Point value will remain for 5 seconds on the LED display as a confirmation of the new value you have selected The Set Point indicator shows the desired temperature NOT the actual temperature Temperature can be adjusted in 1 F 0 5 C increments from 105 120 F 40 0 49 0 C When ambient temperature...

Page 17: ...iquid Level Circuit Board ABSP02796 _____________________________________ Transformer ABSP02779 _____________________________________ Water Feed Solenoid ABSP02778 _____________________________________ Contactor ABSC02787 ABSP02775 ABSC02789 ABSP02775 ABSC02782 ABSP02777 _____________________________________ Automatic Drain ABDR02771 _____________________________________ Acrylic Shield ABSP02776 _...

Page 18: ...ng or arising from modification or repair by any person not authorized by aquasteam abuse misuse neglect accident incorrect power line voltage fire freezing flood or other Acts of God AQUASTEAM PRODUCTS MUST BE INSTALLED OPERATED AND MAINTAINED IN ACCORDANCEWITH aquasteam S INSTRUCTIONS FAILURE TO FOLLOWTHE INSTALLATION OPERATION OR MAINTENANCE PROCEDURES OR USE OF UNAUTHORIZED PARTS AUTOMATICALLY...

Page 19: ......

Page 20: ...residential steambath generators and control by aquabrass aquabrass com ...

Reviews: