Trim Kit for thermostatic 1/2”and 3/4”
8
last revision: 12/02/2018
aquabrass.com
To service the cartridges
Entretien des cartouches
Maintenance
Shut off the main water supply, then remove all the
components from (1) to (12). (See Fig.4). Afterwards,
close the 2 check valves (15) by turning them clock-
wise with a screwdriver. Remove the thermostat car-
tridge screw (16), and pull the thermostatic cartridge
out (14). To remove the volume cartridge(s) (13), un-
screw them directly. Inspect for accumulated debris.
To clean the thermostat cartridge, you may need to
soak it in a vinegar and water solution to remove lime
build-up. If replacement is necessary or to reinstall the
components, reverse the above steps.
Fermer l’alimentation d’eau principale et démonter
toutes les composants de (1) à (12) (Voir Fig.4). Ensuite,
fermer les deux valves d’arrêt (15) en les vissant dans
le sens des aiguilles d’une montre. Retirer la vis (16),
et enlever la cartouche (14). Pour les poignées de
volume, dévisser la(es) cartouche(s) directement (13).
Inspecter pour éliminer les débris accumulés.
Pour nettoyer la cartouche thermostatique, plonger la
dans une solution d’eau et de vinaigre. S’il est néces-
saire de remplacer ou pour réassembler les com-
posants, inverser les étapes ci-dessus.
13
12
8
7
4
14
16
11
10
9
6 5
2
3
1
15
Fig.4