background image

Updated: 10-09-04

Products info: www.aquabrass.com

INS-SCT3/4-3-E

2     INSTALLING THE ROUGH-IN

3     CONNECTING THE WATER     

3/4” thermostatic valve

#1010

ROUGH-IN CAP

LEVEL

COLD

WATER

HOT

WATER

TOP

NORMAL

4     INSTALLING THE TRIM PLATE AND

THE CONTROL HANDLE

SUPPLEMENTARY

OUTLET

A.

When the wall is finished

and you have checked the
access to the rough, you are
now ready to install the trim.

B.

To install the trim, first

thread on the collar (5) to the
body of the cartridge.  Next,
take the trim plate (7) and
secure nylon washer (10) from
the rear of the plate into the
large center hole.  At the same
time, remove the tape and
mount the large foam gasket
(11) on the back of the trim
plate.  Now slide the plate (7)
over the collar (5) and secure
the plate to the body with fin-
ished screws (6) mounting
them in the 2 countersink holes

Fig.5.

C.

Next, install the tempera-

ture stop (4) exactly like illus-
trated in 

Fig. 6 & 7.

D.

Slide the handle-body (3)

on the broach of the cartridge.
Make sure the red button of the
handle is aligned to the 

100F

position

as indicated on the

trim plate (7).  Secure it in
place with the screws (2).  To
check the installation, turn the
handle to the left and to the
right and if correctly installed,
the red button of the handle-
body will stop at the 100F posi-
tion.

E.

Now tighten the cap han-

dle (1) to the handle body (3).

Fig. 8.

ATTENTION: When you turn
on the water with the han-
dle in this position (100F)
and the water temperature
is too hot or too cold,
please refer to the “water
temperature adjustment”
step.

Fig.7

Fig.6

Fig.5

Fig.8

RED
BUTTON

PRINCIPAL

OUTLET

A.

This thermostatic valve can be installed in the 

2x4 

or the 

2x6

wall depending on the available space. Place the rough-in cap (fixed
on the valve) to the desired depth 

3 1/8”

(from the center of the

inlet to the finished wall: gyproc and tile).

B.

For better support, it’s recommended to fit a 3/4” piece of  ply-

wood  to the back of the valve.  Before fitting the valve, make sure
that you have the exact depth in the wall.  Adjust if necessary and
then fit it temporarily with 2 screws. 

C.

To complete the valve installation, correct the horizontal and

vertical alignment of the mixer on the wall using a level placed on the
rough-in cap.  Then adjust and screw it firmly to the back support.

N.B.: For the position of the valve and other accessories, please con-
sult

The Mounting shower system guide.

Fig.3

Fig.4

STOPPER
MARK

A.

Install the thermostatic valve by connecting the hot and cold

water pipes and the mixed water delivery pipe.  

The hot water

must always be connected on the left and the cold water on
the right as indicated on the body

.  Ensure the piping is free of

debris and dirt to prevent blockage in the mixer.

B.

The thermostatic valve is fitted with 2 outlets for the mixed

water (A) and (B).  If it is necessary to use the second one (B), 
connect the supplementary pipe. 

C.

When the water connections have been made, make sure there

are no leaks between the pipes and the valve.

D.

Make sure you seal in the plug on outlet B if you are not going

to use this waterway.

It is important that you run all your shower equipment off
the principal outlet (A).  If you decide to use supplementary
outlet (B) for anything other than a spout, you can expect a
3-5 degree temperature change from that outlet for the ini-
tial seconds of use until the cartridge is able to adust.

SEAL PLUG

Summary of Contents for 1010

Page 1: ...ting the depth of the valve in the wall If you look closely at the rough in cap you will see the Min and Max written on it That means that the thickness of the finished wall must be in between those two marks so the valve can take the minimum depth at 2 5 8 and the maximum depth of 3 5 8 The depth recommended is 3 1 8 from the center of the inlet B The rough in cap is be used as a guide to cut a h...

Page 2: ...is thermostatic valve can be installed in the 2x4 or the 2x6 wall depending on the available space Place the rough in cap fixed on the valve to the desired depth 3 1 8 from the center of the inlet to the finished wall gyproc and tile B For better support it s recommended to fit a 3 4 piece of ply wood to the back of the valve Before fitting the valve make sure that you have the exact depth in the ...

Page 3: ...g all the finished trim open the 2 check valve stops 26 with a screwdriver and follow step 4 or 5 TO SERVICE THE CARTRIDGE TAKING CARE OF YOUR AQUABRASS PRODUCT To clean your AQUABRASS faucet or accessory wash with a wet non abrasive soapy cloth Then wipe dry with a soft towel or cloth We recommend this be done on a regular basis DO NOT USE ANY ABRASIVE CHEMICAL OR CORROSIVE POWDER OR ANY OTHER ST...

Page 4: ...4 With 3 4 thermostatic valve Recommended Installation Mounting shower system guide Kit 3 NOTES The length of the pipes from the center to the body jets should be of equal distance to create equal pressure All dimensions are recommendations only and can be adjusted to the users preference ...

Reviews: