background image

168.28

6 5/8"

1/2"N.P.T.

1/2" N.P.T.

99.70

3 15/16"

100.33

3 15/16"

120.90

4 3/4"

148

5 13/16"

1/2 N.P.T.

1/2" N.P.T.

2 7/16" [61.9] Min.

3 1/8" [79.4] Max.

Updated: 09-17-09

1/2” thermostatic valve

The thermostatic valve # 1004 is protected by a plastic protective

covering.  It can be used for different functions :

A. It can be used as a rough-in cap for setting the depth of the

valve in the wall.  If you look closely at the rough-in cap, you will see

the Min and Max written on it.  That means that the thickness of the

finished wall must be in between those two marks, so the valve can

take the minimum depth at 2 7/16” and the maximum depth of 3 1/8”.

The depth recommended is 2 3/4” from the center of the inlet.

Products info: www.aquabrass.com

I N S T A L L A T I O N   P R O C E D U R E S

1     HOW TO USE THE ROUGH-IN CAP  

#1004

ROUGH-IN 

CAP

ATTENTION:  

MAKE SURE TO FLUSH THE HOT AND COLD WATER

SUPPLY LINES BEFORE BEGINNING THE INSTALLATION.

3 1/2"

88.90

5 1/2"

139.70

62.2

2 7/16"

Min.

80

3 1/8"

Max.

155.58

6 1/8"

70.04

2 3/4"

99.70

3 15/16"

41.66

1 5/8"

33.02

1 5/16"

71.76

2 13/16"

Ø

41.40

1 5/8"

123.19

4 7/8"

70

2  3/4"

B. The rough-in cap is also used

for the finished wall cutout. This

insures access for servicing the valve

at a future date.

C. The rough-in cap also protects

the valve during installation by 

different trades.

TILE

GYPROC

2X4

2X6

ROUGH-IN CAP

SUPPORT 

RECOMMENDED

Fig.2

Fig.1

FINISHED WALL

Summary of Contents for 1004

Page 1: ...pth at 2 7 16 and the maximum depth of 3 1 8 The depth recommended is 2 3 4 from the center of the inlet Products info www aquabrass com I N S T A L L A T I O N P R O C E D U R E S 1 HOW TO USE THE ROUGH IN CAP 1004 ROUGH IN CAP ATTENTION MAKE SURE TO FLUSH THE HOT AND COLD WATER SUPPLY LINES BEFORE BEGINNING THE INSTALLATION 3 1 2 88 90 5 1 2 139 70 62 2 2 7 16 Min 80 3 1 8 Max 155 58 6 1 8 70 04...

Page 2: ... LEVEL COLD WATER HOT WATER TOP NORMAL 4 INSTALLING THE TRIM PLATE AND THE CONTROL HANDLE SUPPLEMENTARY OUTLET USE INDEPENDENTLY FROM A A When the wall is finished and you are ready to trim the valve first remove the plastic template from the body Check your access to the rough you are now ready to mount the trim B Remove the tape and mount the large foam gasket 30 on the back of the trim plate 7 ...

Page 3: ...ridge of the shut off valve 22 use a ratchet and socket 17mm Insert a new cartridge and tighten Before remounting all the finished trim open the 2 check valve stops 26 with a screwdriver and follow step 4 5 and 6 CLEANING THE CHECK VALVE TAKING CARE OF YOUR AQUABRASS PRODUCT To clean your AQUABRASS faucet or accessory wash with a wet non abrasive soapy cloth Then wipe dry with a soft towel or clot...

Page 4: ...pdated 18 08 04 Products info www aquabrass com AQ PRO 2 With 1 2 thermostatic valve NOTES All dimensions are recommended and can be adjusted properly by the user HOT COLD KIT 2 Recommended Installation ...

Page 5: ... 09 17 09 Info Produits www aquabrass com INS SCT2 1 F P R O C É D U R E D I N S T A L L A T I O N 1 UTILISER LE GABARIT 1004 GABARIT ATTENTION ASSUREZ VOUS DE BIEN VIDANGER L ALIMENTATION EN EAU CHAUDE ET FROIDE AVANT DE COMMENCER L INSTALLATION DE LA VAVLE 3 1 2 88 90 5 1 2 139 70 62 2 2 7 16 Min 80 3 1 8 Max 155 58 6 1 8 70 04 2 3 4 99 70 3 15 16 41 66 1 5 8 33 02 1 5 16 71 76 2 13 16 Ø 41 40 1...

Page 6: ...a vis de blocage 16 Glisser ensuite les composantes 12 13 14 et 17 de la manette autour de l adaptateur 10 Assurer que le bouton rouge du poussoir 13 est à la posi tion 100F Fixer le poussoir 13 en serrant la vis de blocage 16 à l aide de la clé hexagonale Replacer toutes les composantes et refermer le capuchon 20 Fig 7 Fig 7 Fig 6 Fig 5 BOUTON ROUGE ARRÊT 5 INSTALLER LA POIGNÉE Installer le corps...

Page 7: ...ur enlever la cartouche de la valve shut off 22 utiliser une clé à rochet 17mm Introduire la nouvelle cartouche et la serrer Avant de remonter les composantes en suivant les étapes 4 5 et l étape 6 au besoin réouvrir les 2 check valves 26 avec le tournevis NETTOYAGE DES CHECK VALVE A Avant de commencer assurerez vous de bien vidanger l alimentation en eau chaude et froide B Ensuite enlever tous le...

Page 8: ...Products info www aquabrass com AQ PRO 2F Kit 2 NOTES Toutes les dimensions suggérées peuvent varier selon les besoins de l usager E C E F Avec valve thermostatique 1 2 GUIDE DE MONTAGE DES DOUCHES Installation suggérée ...