  Chose  the  Data  Input  Mode 

dIn

  of  the  Dosing  Cycle  Operation  mode: to enter  and  exit  the  submenu, use 

the 

Enter

 

key, to browse through the “

tIn/ G.nC

” entries use 

▲ 

and

 

▼. This section of the Menu will not be 

displayed if the Relay mode has been selected from the previous 

rEL

 entry; 

 

  Set  the  duration  of  the  Delay  Phase  for  the  programmable  cyclic  mode, 

dlt

,  within  a  range  from  0 

(deactivated)  to  999  seconds:  to  enter  and  exit  the  submenu,  use  the 

Enter

  key,  to  browse  through  the 

values use 

▲ 

and

 

▼. This section of the Menu wil

l not be displayed if the Relay mode, has been selected 

from the previous 

rEL

 entry; 

 

  Set  the  duration  of  the  dosing  Phase  for  the  programmable  cyclic  mode, 

do.t

,  within  a  range  of  1-99 

minutes. To enter and exit the submenu, use the 

Enter

 key, and browse through the values with 

▲ 

and

 

▼. 

This section of the Menu will be displayed if the Relay operating mode, 

rEL

, has not been selected, and the 

data input mode is equal to 

tIn

 

  Set the amount of product to be dosed in g/cu. m. of water for the programmable cyclic mode, 

G.nC

, within a 

range of 0-99.9/ 100-999. To enter and exit the submenu, use the 

Enter

 key, and browse through the values 

with 

▲ 

and

 

▼. This section of the Menu will be displayed if the Relay operating mode, 

rEL

,  has not been 

selected, and the data input mode is equal to 

G.nC

 

  Set  the  density  of  the  product  to  be  dosed, 

dEn

,  for  the  programmable  cyclic  mode,  expressed  as  the 

difference from the reference value of 1000 g/l, within a range of -50 

÷

 500, i.e. from 950 g/l to 1500 g/l: To 

enter  and  exit  the  submenu,  use  the 

Enter

  key,  to  browse  through  the  value  use  the  keys

▲ 

and

 

▼;  this 

entry of the Menu will be displayed in case the Relay mode has not been selected through 

rEL

, and the data 

input mode is equal to 

G.nC

 

  Set the capacity of the pool in cu. m. 

P.nc

, within a range of 1-999. To enter and exit the submenu, use the 

Enter

 key, and browse through the values with 

▲ 

and

 

▼. This section of the Menu will be displayed if the 

Relay operating mode, 

rEL

, has not been selected, and the data input mode is equal to 

G.nC

 

  Set  the  duration  of  the  Block  Phase  for  the  programmable  Cyclic  Mode, 

bL.t

,  within  a  range  of  0 

(deactivated)  -  99  minutes.  To  enter  and  exit  the  submenu,  use  the 

Enter

  key,  and  browse  through  the 

values with 

▲ 

and

 

▼. This section of the Menu will be displayed if the Relay operating mode, 

rEL

, has not 

been selected; 

 

  Select  if  the  cyclic  programmable  mode  must  be 

Repeat 

(see  Operation  section,  Chap.  3.1) 

r.St

:  to  enter 

and exit the submenu, use the 

Enter

 key, to browse through the values use 

▲ 

and

 

▼. This section of the 

Menu will not be displayed if the Relay mode, 

rEL

 has been selected; 

 

  Set  the  stabilization  time  of  the  inhibiting  signal, 

Stb

,  coming  from  the  swimming  pool  recirculation  pump, 

within a range of 1-999 seconds: to enter and exit the submenu, use 

Enter

, to scroll through the values use 

the ▲ and ▼ keys;

 

 

  Set the time of the pump maintenance alarm, 

O.F.d

, from 0 (disabled) to 999 hours, based on the following 

format: 

h.mm 

up to 9 h and 59 m

 

hh.m  

up to 99 h and 59 m (minutes expressed in tens)

 

hhh   

up to 999 h

 

To enter and exit the submenu use 

Enter

 and increase/decrease the value with the 

▲ 

and

 

▼ keys;

 

 

  Access the 

In.t

 inhibiting signal recognition  window: to enter and exit the submenu use 

Enter

. The display 

will show the status identified by the pump for the input signal:  

    Steady "HI"

: enabling signal identified as active; 

Steady "Lo"

: enabling signal identified as not active; 

Flashing “HI”: 

enabling signal identified as active, but slightly above the identification voltage threshold; 

Flashing "Lo":

 enabling signal identified as not active, but slightly below the identification voltage threshold; 

If  the  status  displayed  does  not  correspond  to  the  actual  status  of  the  signal  or  if  the  status  displayed  is 
flashing, just scroll with the

▲ 

and

 

▼ keys to change the threshold, namely:

 

Status of the non-active signal (recirculation pump OFF): 

if the signal is identified as active (steady or flashing 

HI

) or not active but near the threshold (flashing 

Lo

), 

press ▼ to reduce the threshold voltage until a steady “

Lo

” is displayed;

 

  if  the  signal  is  permanently  identified  as  not  active  (steady 

Lo

),  conduct  a  check  when  the  signal  is 

activated; 

Summary of Contents for Simpool Pool-T

Page 1: ...E Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 1 72 Simpool Modello Pool T For other languages please visit http aqua quickris com simpool pool t ITALIANO Manuale...

Page 2: ...AVVIO RAPIDO Modalit Ciclo di Dosaggio a Quantit 14 3 3 PROGRAMMAZIONE AVANZATA 15 3 3 1 Impostazione della Lingua 15 3 3 2 Visualizzazione e Reset delle Statistiche 15 3 3 3 Taratura della Pompa 16 3...

Page 3: ...ere inferiore o uguale a quella nominale della pompa Al momento del ricevimento assicurarsi dell integrit della pompa e di tutte le sue componenti in caso di anomalie avvisare immediatamente il person...

Page 4: ...superiore a 15 Lontana da fonti di calore in luoghi asciutti ad una temperatura massima di 40 C e minima 0 C In un ambiente ventilato e facilmente accessibile ad un operatore per effettuare periodicam...

Page 5: ...A MURO Per fissare a muro la pompa eseguire le seguenti operazioni Fissare la staffa al muro con il corredo dei tasselli e viti in dotazione Inserire la pompa sulla staffa Verificare la stabilit del f...

Page 6: ...a d iniezione Fig 2 b Montaggio Valvola d iniezione Rif Descrizione 1 Ghiera Fissatubo PP Nera 1 8 4x6 STD cod ADSP5004001E 2 Raccordo Corpo pompa PP nero 3 8 4x6 cod ADSP5005001E 3 O ring Viton Nero...

Page 7: ...mpa siano compatibili con quelli della rete elettrica Non installare mai la pompa direttamente in parallelo a carichi induttivi es motori Elettrovalvole ma se necessario usare un rel d isolamento All...

Page 8: ...Simpool Modello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 8 72 Fig 4 Installazione...

Page 9: ...tre posizioni la pompa attiva ON O la pompa spenta OFF la pompa in adescamento MOM La posizione MOM monostabile per cui dopo aver posizionato l interruttore in MOM al rilascio l interruttore si ripos...

Page 10: ...il tempo di blocco risulti attivo e stabilizzato Il segnale inibitore si sia disattivato e nuovamente attivato Nella figura seguente Fig 7 a b sono riportati gli schemi di funzionamento del modo Ciclo...

Page 11: ...di prodotto verr calcolata anche sulla base della densit in g l impostata per il prodotto utilizzato La formula 3 1 indica il calcolo effettuato per ricavare il tempo di dosaggio della pompa nel Ciclo...

Page 12: ...so di funzionamento a Ciclo di Dosaggio durante la fase di blocco della pompa in attesa del ciclo di dosaggio successivo in alternanza al valore in minuti o in secondi del countdown FIn Fine Ciclo Dos...

Page 13: ...larmi ogni schermata del Menu Iniziale e del Menu Utente sar visibile in alternanza alla voce di segnalazione dell allarme pi prioritario vedi sezione Allarmi Menu Programmazione Il Menu Programmazion...

Page 14: ...mento della pompa sono i seguenti Tempo di Ritardo Grammi al metro cubo di Prodotto Densit Prodotto Tempo di Blocco Dal Menu Utente si potr procedere rapidamente con le seguenti operazioni Adescamento...

Page 15: ...i stand by i dati programmati andrebbero persi 3 3 1 Impostazione della Lingua Dalla voce LIn sar possibile scegliere la lingua tra Italiano It e inglese En tramite i tasti per entrare e per uscire us...

Page 16: ...ura della Pompa La taratura della pompa consente di ottenere dei dosaggi pi precisi poich permette di correggere il tempo di dosaggio in funzione della portata effettiva della pompa nel caso in cui no...

Page 17: ...e InP del Menu di Programmazione tramite tasto Enter si accede al Menu Impostazioni Dal Menu Impostazioni possibile effettuare le seguenti operazioni fare riferimento alla Figura 15 Impostare la passw...

Page 18: ...l alla voce rEL e la modalit di immissione dati pari a G nC Impostare la capacit della piscina in metri cubi nC P nel range 1 999 per entrare e per uscire dal sottomenu usare il tasto Enter per scorre...

Page 19: ...fisso passare all eventuale verifica a disattivazione del segnale Scegliere se rendere modificabile il valore dei parametri da Menu Utente on line OnL per entrare e per uscire dal sottomenu usare il t...

Page 20: ...da seguire per il corretto funzionamento della pompa e le operazioni da effettuare periodicamente per mantenere le condizioni ottimali nel tempo 5 1 NORME GENERALI Le operazioni di manutenzione vanno...

Page 21: ...ino frontale Fase 2 Rotazione rullino in senso orario e sgancio della ghiera di aspirazione sx dalla sede Fase 3 Rimozione del tubo Fase 4 Sgancio della ghiera di mandata dx dalla sede e rimozione com...

Page 22: ...DICE D che il materiale sia compatibile con il prodotto dosato e quindi procedere alla sostituzione Problema perdite di liquido dal tubo peristaltico Soluzione 1 Controllare che il tubo di mandata e d...

Page 23: ...nque esclusa qualsiasi altra responsabilit ed obbligazione per altre spese danni e perdite dirette o indirette derivanti dall uso o dall impossibilit di uso delle pompe sia totale che parziale La ripa...

Page 24: ...Simpool Modello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 24 72 APPENDICE A Ingombri...

Page 25: ...imento Topografico Scheda Elettronica 1 2 3 4 5 6 Rif Descrizione A LED bicolore B Display 3 Digit a 7 segmenti C Porta rullini D Tubo peristaltico E Raccordo di aspirazione F Raccordo di mandata Rif...

Page 26: ...odello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 26 72 APPENDICE C Esplosi 2 1 3 21 7 16 13 10 17 11 8 9 5 6 4 19 18 14...

Page 27: ...1 9 ADSP9600002 CASSA POSTERIORE PERISTALTICA SIMPOOL 1 10 ADSP6000948 PROTEZIONE BNC FEMMINA DA PANNELLO GOMMA NERO 2 11 ADSP6000685 INTERRUTTORE ON OFF PAUSA 3A 250V TIPO A BILICO 1 12 ADSP6000686 C...

Page 28: ...1 1 3 1 Acido Nitrico 65 HNO3 1 1 2 3 1 1 1 3 3 2 Acido Solforico 85 H2SO4 1 1 1 1 1 1 1 3 3 1 Acido Solforico 98 5 H2SO4 1 1 3 3 1 1 1 3 3 3 Ammine R NH2 1 2 1 3 1 1 3 2 3 1 Bisolfato di sodio NaHSO3...

Page 29: ...3 2 3 Acido fosforico H3PO4 1 1 1 Acido Nitrico 68 71 HNO3 3 3 3 Acido Solforico 30 H2SO4 1 1 1 Acido Solforico 95 98 H2SO4 3 3 2 Ammine R NH2 2 3 1 Solfati di sodio NaHSO3 1 1 1 Carbonato di Sodio so...

Page 30: ...Densit Prodotto 0 1000 g l G nC Grammi al metro cubo 1 LIn Lingua En nC P Metri cubi piscina 100 n I d Modalit Immissione Dati tnP O F d Tempo di Manutenzione 0 sec disabilitato OnL On Line SI PAS Pas...

Page 31: ...to HI Lo HI Lo Alto Basso Livello Segnale Inibitore InP InP Impostazioni LIn Lan Lingua nC P P nc Metri cubi della piscina nL nL ml O F d O F d Tempo di Manutenzione OnL OnL On Line Calibrazione PAS P...

Page 32: ...odello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 32 72 APPENDICE G Mappa del Menu Menu Iniziale Menu Utente Modo Ciclic...

Page 33: ...Simpool Modello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 33 72 Modo Ciclico a Quantit Modalit Rel...

Page 34: ...Simpool Modello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 34 72 Menu Programmazione...

Page 35: ...Simpool Modello Pool T MANUALE ISTRUZIONE e MANUTENZIONE Pompa peristaltica digitale programmabile ITALIANO ADSP7000642 rev 1 0 13 01 2014 35 72 Menu Statistiche Menu Impostazioni...

Page 36: ...e i dispositivi elettrici ed elettronici alla fine della loro vita utile a degli idonei centri di raccolta differenziata Il simbolo del cassonetto barrato riportato sul prodotto sul manuale d istruzio...

Page 37: ...g Cycle Mode 48 3 2 2 QUICK START UP Quantity Dosing Cycle Mode 49 3 3 ADVANCED PROGRAMMING 50 3 3 1 Setting the Language 50 3 3 2 Displaying and Resetting Statistics 50 3 3 3 Calibrating the Pump 51...

Page 38: ...e integrity of the pump and all of its parts Should there be any anomalies promptly notify qualified personnel before performing any operations This manual must be kept in a safe place for future refe...

Page 39: ...l position with an inclination below 15 Away from sources of heat in dry locations at a maximum temperature of 40 C and a minimum of 0 C In a ventilated location that can be easily accessed for period...

Page 40: ...ALL MOUNTING Proceed as follows to secure the pump to the wall Fix the bracket to the wall using the wall plugs and screws supplied Place the pump on the bracket Ensure the fixing is stable It is also...

Page 41: ...Injection valve Fig 2 b Injection valve assembly Ref Description 1 Black PP pipe clip 1 8 4x6 STD code ADSP5004001E 2 Black PP Pump body fitting 3 8 4x6 code ADSP5005001E 3 Black Viton O ring code AD...

Page 42: ...le with those of the mains Never install the pump directly in parallel with inductive loads e g motors solenoid valves If necessary use an isolating relay There are two protection devices inside the p...

Page 43: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 43 72 Fig 4 Installation...

Page 44: ...ing the Programming Menu Flashing orange Pump priming in progress The switch has three positions the pump is active ON O the pump is off OFF the pump is priming MOM The MOM position is monostable ther...

Page 45: ...wing dosing cycle will start if at least one of the following conditions is fulfilled The Repeat operating mode has been selected and the inhibitory signal is active and stabilized at the end of the b...

Page 46: ...the pool and of the quantity of product to be dosed for each cu m of water Quantity Dosing Cycle The quantity of product will be calculated also on the basis of the density in g l set for the product...

Page 47: ...es or seconds bLC Block Phase displayed during the pump s block phase of the Dosing Cycle while waiting for the following dosing cycle to start alternately to the countdown value expressed in minutes...

Page 48: ...nitial Menu by pressing the F key for 3 seconds If there are one or several active alarms every page of the Initial Menu and of the User Menu will be alternated to the entry that reports the alarm wit...

Page 49: ...e fundamental parameters to be set to activate the pump Delay Time Grams per Cu M of Product Product Density Block Time From the User Menu you can proceed quickly with the steps below Prime the pump D...

Page 50: ...lay programmed data is lost 3 3 1 Setting the Language From the LAn entry you can choose between Italian It and English En via the keys Use Enter to enter and exit Fig 11 Fig 11 Setting the Language 3...

Page 51: ...ds 3 3 3 Calibrating the Pump The calibration of the pump allows to achieve more accurate dosing as it allows to correct the dosing time in relation to the actual flow rate of the pump If the calibrat...

Page 52: ...Pt entry of the Programming Menu via the Enter key you can access the Settings Menu From the Settings Menu you can carry out the following operations refer to Figure 15 Set the password to access the...

Page 53: ...on of the Menu will be displayed if the Relay operating mode rEL has not been selected and the data input mode is equal to G nC Set the duration of the Block Phase for the programmable Cyclic Mode bL...

Page 54: ...1 MAINTENANCE ALARM The maintenance alarm is activated when the pump has been running for longer than the time set in the relevant O F d submenu see Settings Menu If you set 0 00 h mm as a time value...

Page 55: ...reported below to the letter It is difficult to define the standard times required for maintenance beforehand as there are a number of factors that determine the wear of the pump and in particular the...

Page 56: ...p 1 Open the front glass Step 2 Turn the roller clockwise and release the left suction ring nut Step 3 Remove the tube Step 4 Release the right delivery ring nut and remove it completely Fig 16 Remova...

Page 57: ...ct being dosed by consulting the chemical compatibility table see ANNEX D and then go ahead with the replacement Problem liquid leaking from the peristaltic tube Solution 3 Make sure the delivery and...

Page 58: ...r is nevertheless excluded from any other responsibility and obligation regarding other expenses direct or indirect damage and losses deriving from the use or from the impossibility either total or pa...

Page 59: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 59 72 ANNEX A Overall dimensions...

Page 60: ...Reference Figures Electronic Board layout 1 2 3 4 5 6 Ref Description A Two coloured LED B 3 digit display with 7 segments C Roll holder D Peristaltic tube E Intake fitting F Delivery fitting Ref Desc...

Page 61: ...Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 61 72 ANNEX C Exploded views 2 1 3 21 7 16 13 10 17 11 8 9 5 6 4 19 18 14 2...

Page 62: ...Vac 1 9 ADSP9600002 SIMPOOL PERISTALTIC REAR FRAME 1 10 ADSP6000948 FEMALE BNC PROTECTION FROM BLACK RUBBER PANEL 2 11 ADSP6000685 3A 250V ON OFF PAUSE FLIP SWITCH 1 12 ADSP6000686 CLEAR PROTECTIVE CO...

Page 63: ...1 1 1 3 1 Nitric Acid 65 HNO3 1 1 2 3 1 1 1 3 3 2 Sulphuric Acid 85 H2SO4 1 1 1 1 1 1 1 3 3 1 Sulphuric Acid 98 5 H2SO4 1 1 3 3 1 1 1 3 3 3 Amines R NH2 1 2 1 3 1 1 3 2 3 1 Sodium bisulphite NaHSO3 1...

Page 64: ...2F2 3 2 3 Phosphoric acid H3PO4 1 1 1 Nitric Acid 68 71 HNO3 3 3 3 Sulphuric Acid 30 H2SO4 1 1 1 Sulphuric Acid 95 98 H2SO4 3 3 2 Amines R NH2 2 3 1 Sodium sulphates NaHSO3 1 1 1 Sodium Carbonate soda...

Page 65: ...sity 0 1000 g l G nC G nC Grams per cu m 1 LIn LAn Language En nC P P nc Volume of the pool 100 n I d d I n Data Input Mode tnP O F d O F d Maintenance Time 0 sec disabled OnL OnL On Line SI PAS PAS P...

Page 66: ...Product HI Lo HI Lo High Low Inhibiting Signal Level InP OPt Settings LIn Lan Language nC P P nc Cu m of the pool nL nL ml O F d O F d Maintenance Time OnL OnL On line Calibration PAS PAS Password rE...

Page 67: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 67 72 ANNEX G Menu Layouts Initial Menu User Menu Timed Cyclic Mode...

Page 68: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 68 72 Quantity Cyclic Mode Relay Mode...

Page 69: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 69 72 Programming Menu...

Page 70: ...Simpool Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 70 72 Statistics Menu Settings Menu...

Page 71: ...e obliged by law to return to the specific collection and recycling centres the electrical and electronic devices at the end of their useful life Products labelled with the crossed out wheeled been or...

Page 72: ...ol Pool T Model INSTRUCTION AND MAINTENANCE MANUAL Programmable digital peristaltic pump ENGLISH ADSP7000642 rev 1 0 13 01 2014 72 72 For other languages please visit http aqua quickris com simpool po...

Reviews: