It is also important not to fix the filter too close to the floor, otherwise 
it  becomes  impossible  or  difficult  to  remove  the  cartridge  when 
carrying out the necessary maintenance. 
 
The minimum recommended distance from the wall is 80 mm. 
The minimum distance from the floor is 25 mm. The recommended 
distance is instead of 100 mm (or more). 
 
 
Depending  on  the  size  of  the  filter  purchased,  it  is  possible  to 
determine  the  fixing  point  of  the  bracket  using  the  following  table, 
where the dimensions of the filter can also be deduced: 
 
To connect the filters to the pipes, use 
flexible fittings to avoid possible tensions 
caused by the pipes. 
 
It is, in fact, preferable not to connect the 
threaded pipes directly to the device. 
Pipes can be used for welding, pressure or 
with union. 
 

Summary of Contents for KID P2

Page 1: ...e for domestic use to carry out a turbidity filtration treatment AQUA KID P2 AQUA KID P3 AQUA KID filters can contain cartridges of various kinds depending on the type of treatment to be carried out on the incoming drinking water In particular AQUA spa makes available for these filters Wire wound cartridges Mod FA KID Melt Blown polypropylene cartridges Mod FR N KID Washable mesh cartridges Mod RL...

Page 2: ......

Page 3: ...P Their typical installation scheme is as follows GENERAL WARNINGS This filter is an equipment for the treatment of drinking water made in compliance with the DM 25 12 and DM 174 04 the user must use it in full compliance with this manual in order to avoid potential risks to health or safety This filter is suitable for the filtration and treatment of drinking water as defined by the competent auth...

Page 4: ...s not recommended This equipment requires regular periodic maintenance in order to ensure the maintenance of the drinking water requirements of the treated water INSTALLATION The installation of the filter must be performed by qualified personnel capable of issuing a regular declaration of conformity The typical filter assembly scheme is the one shown in the image alongside It is advisable to crea...

Page 5: ... The recommended distance is instead of 100 mm or more Depending on the size of the filter purchased it is possible to determine the fixing point of the bracket using the following table where the dimensions of the filter can also be deduced To connect the filters to the pipes use flexible fittings to avoid possible tensions caused by the pipes It is in fact preferable not to connect the threaded ...

Page 6: ...he sump After placing the cartridge in the sump put the O Ring in its seat and screw the sump clockwise onto the head It is recommended to tighten tightly but by hand without using the key If once put into operation drips occur tighten further with the aid of the key Re open the water check that there are no drips and vent the vessel by slightly opening the vent screw on the head or by pressing th...

Page 7: ...l pressure of the filter Place a low container on the floor to collect the water that will drip from the filter when it is opened or some rags to collect the water Disassemble the sump using the special plastic key Be careful not to drop the sump It is sensitive to shocks Be careful not to lose the O Ring and check that it is not damaged Otherwise recover a new O Ring Remove the cartridge and elim...

Page 8: ...roduct is guaranteed in accordance with the provisions of the AQUA SPA General Conditions of Sale document The details of the guarantee provide that The item is used according to the instructions given by the manufacturer Installation and maintenance are carried out following the manufacturer s instructions The replacement under warranty is made only against the return of defective material and af...

Reviews: