AQUA ULTRAVIOLET | 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 | TEL: (800) 454-2725 or (951) 296-3480
INSTRUCTIONS CONTINUE
Remote Control Instructions
(select mode before using)
1.
Two mode
s
: standard mode and automatic mode, swi
tch
button
is located under
back battery.
2.
Standard mode
3.
Automatic mode
4.
Press the "lock" button
t
o start.
C
hoose any button, i
t
will take around 12 seconds
t
o turn on after
it stops beeping
.
5.
The
beeping
warns you
to move away from
the disinfection area
,
ASAP
.
6.
Five different disinfection time setting
s
(ON/30MIN/60MIN/90MIN/120MIN); "ON" means no
t
time limited.
7.
If you want to cancel the time setting, press OFF. Each time the lamp sounds around 12 seconds then on without detection.
8.
The
remote controller is
paired to the lamp
.
Note: Other buttons are out of function, if the "lock button"
is
not pressed
Remote
C
ontrol
B
attery
I
nstallation
I
nstructions
Insert 2 AAA alkaline batteries, please pay attention to the polarity of the battery, and it is strictly prohibited to mix new and old batteries.
1.
Press the "LOCK" button before operating other function buttons.
2.
After the UVC lamp is working normally, the lamp is turned off by the artificial trigger sensor module. If there is no abnormal detection within 2
minutes, the lamp will automatically turn on and work normally. The suspended time will not count in the timer.
3.
The signal of the remote control is a non-linear wave signal, and
may detect movement through some walls.
CAUTIO
N
TECHNICAL SPECIFICATIONS
Operating Temperature :
14
-+
9
5
°F
Operating Environment Humidity: <80%
Storage Temperature: -
4
-+
140°F
Sensor Detection Range: 360 degrees
Sensor Detection Distance: 0-
16
feet
Sensor Type: 1 Mi 3 PIR sensors
Remote Control Distance:
3
3
feet
Principles and Sterilization Factors
Sterilization Factor: Ultraviolet 253. 7nm
The Principle of Sterilization: Use the C-band ultraviolet light emitted by the ultraviolet
lamp to destroy the bacteria and DNA of bacteria for sterilization.
Sensor detection distance: 16ft
2