60
mm
9
Implement appropriate measures to attenuate the noise
generated by the pump to avoid damage to the environment.
Fastening the pump to the foundation should be effected
exclusively by means of bolts, threads or dowels, in order
to avoid blocking the removal of the motor unit! Make sure
that there is enough space between fan cover and wall,
minimum 60 mm.
Caution
When the pump is installed outside, we recommend to foresee
a simple protection against the weather (rain, sun etc.).
Caution
Keep the suction path as short as
possible. The pump should be
installed in horizontal position and in
a dry place. The Aqua Splash is
non-self priming and therefore must
be installed below water level (max.
gravity feed 3 m). A shutoff valve has
to be installed on the suction line
and on the pressure line.
Caution
We recommend the use of a spiral hose and a hose clamp to
connect the pump to the pool. The connection to the pump is
easy to undo and can be realised in several ways due to the
use of nozzles.