Aqua Systems Electric KFC Series Instruction Manual Download Page 6

INSPECTION

 

 

1.

 

Check if the pump is connected to a compatible source of electric power.

 

2.

 

Make  sure  the  pump  has  contact  with  liquid,  which  is  going  to  be  transferred                 
(running the pump in a constant dry state is strictly forbidden).

 

3.

 

Make sure the ground wires are connected and the switch is turned OFF.

 

4.

 

If transferring a certain liquid may easily lead to static electricity occurrence, by all 
means use a ground wire not only with the motor, but also with liquid

s container.

 

 

USAGE

 

 

1.

 

Open the valve 

, insert device

s suction pipe into the liquid. 

2.

 

Make sure the switch is turned off. Connect the device to the power source. 

3.

 

Close the valve 

  and turn the switch ON. Then open the valve 

  gradually, to 

adjust the delivery rate. 

4.

 

After use

turn the switch OFF and unplug the device from the power source.

 

[Valve 

  location is marked on the next page.] 

 

TECHNICAL SPECIFICATIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 

KFC103-N 

KFC104-N 

Max delivery rate 

80L/min 

Max uplift (clear water) 

16m 

14m 

Max temperature 

60℃

 

Operated by 

ELECTRIC MOTOR 

Power source AC100V 4A (single phase) 

Frequency 

50/60Hz continuous rating 

Power 

160W 

Cord 

PVC, 4.7m 

Summary of Contents for Electric KFC Series

Page 1: ...rum Can Pump for acids alkalis and solvents INSTRUCTION MANUAL Electric KFC Series Contents 1 Safety precautions 2 3 4 Before using the device 5 Inspection usage spec 6 Parts description 7 Warranty an...

Page 2: ...anual misusing the device may result in accidents Keep the manual in a safe place and refer to it when necessary 1 Not following the instructions may result in death or serious injuries Not following...

Page 3: ...ssemble or regulate the device Doing so permanently invalidates the warranty Refer to the permitted liquids list This pump has been designed for acids alkalis and solvents transfer however there are a...

Page 4: ...t doing so may result in dangerous chemical reactions Pay attention to hardening of the hose Transferring some of the liquids may cause hose s hardening with time This may eventually lead to leakage a...

Page 5: ...eping the device plugged may accidentally lead to electric shock and fire Do not pull water or chemicals on the motor It may result in electric shock and fire Transfer liquids of viscosity no higher t...

Page 6: ...t also with liquid s container USAGE 1 Open the valve insert device s suction pipe into the liquid 2 Make sure the switch is turned off Connect the device to the power source 3 Close the valve and tur...

Page 7: ...N OFF Switch 2 Main body head Main body head 3 Valve Plastic 3 4 Valve SUS 3 4 4 Drum can adapter Plastic G2 Drum can adapter Plastic G2 5 Reinforced PVC 2m 25 SUS304 2m 25 6 100V Electric cord 4 7m 1...

Page 8: ...the service will not be free In both cases covering shipment related costs is customer s responsibility Product s breakdown has been reported within 1 year from the date of purchase but The product ha...

Reviews: