Installation, Operation and Maintenance Manual
CAUTION
IMPORTANT NOTES
To reduce the risk associated with property damage due to water leakage:
•
Read and follow Use Instructions before installation and use of this system.
• Installation and Use
MUST comply with all state and local plumbing codes.
•
Protect from freezing. Drain filter when temperatures drop below 40°F (4.4°C).
•
Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 125 psi, you
must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check
your water pressure.
•
Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a
water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
• The system
must be installed on COLD water lines only, maximum temperature is 100°F (37.8°C).
• The system
must be installed with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• The disposable filter cartridge
must be replaced every six months or at the specified service cycle.
•
Do not use a torch or other high temperature sources near filter or plastic fittings.
•
Do not install in direct sunlight.
•
Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount
the bracket.
• Mount filter in such a position as to prevent it from being struck by other items used in the area of installation
(waste baskets, etc).
• On plastic fittings, never use pipe sealant or pipe dope. Use thread sealing tape
only.
•
Ensure all tubing and fittings are secure and free of leaks.
•
Do not install unit if collet is missing. Contact CUNO if collets are missing from any fittings.
•
SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off.
• Shut off inlet water supply and depressurize system as shown in manual when changing cartridges or servicing.
• Failure to follow instructions may void warranty.
• Allow a minimum of 7 1/2” (19.5 cm) clear space under filter to facilitate cartridge change.
• Do not crimp copper tubing.
• Some state and local plumbing codes may prohibit the use of saddle-type valves and/or drain connections.
The use of saddle-type valves are prohibited in: Alaska, Delaware, Idaho, Kentucky, Massachusetts, Michi-
gan, Minnesota, New Hampshire, North Dakota, Ohio, Oregan and South Dakota. Check your local plumb-
ing codes for any restrictions that apply.
• It is mandatory that safety glasses be worn during sink hole drilling operations to prevent eye injury.
2
3
Introduction
This manual explains installation and operation of the Aqua-Pure
®
AP-RO5500 Reverse Osmosis (RO) Drinking
Water Filtration System. Please read each section of this manual carefully.
The Aqua-Pure AP-RO5500 RO Drinking Water Filtration System is designed to connect permanently to a home
plumbing system. To ensure that the installation conforms to your state and local plumbing codes, it is recommended
that the installation be performed by a qualified installation specialist for RO drinking water filtration systems or a
licensed plumber.
The RO module is shipped with a preservative solution. Make sure that you flush the system thorough-
ly as directed before the first use.
NOTE: Make sure that the Owners Warranty Record Card is filled out and mailed within 10 days of installation.
Installation Checklist and Table of Contents
1.
Determine System Location
..................................................................................................................... 4
2.
Prepare the Area for Installation
............................................................................................................... 4
3.
Prepare the Filtration System for Installation
............................................................................................ 4
4.
Install the Feed Water Valve and Tubing
................................................................................................... 5
5.
Prefill and Sanitize the Storage Tank
........................................................................................................ 5
6.
Install the Drain Connection
...................................................................................................................... 6
7.
Install the Faucet
...................................................................................................................................... 6
8.
Make the Faucet Mounting Hole
............................................................................................................... 7
9.
Mount the Faucet
...................................................................................................................................... 8
10.
Make Initial Faucet Tubing Connections
................................................................................................... 8
11.
Install the Purification Assembly and Storage Tank
.................................................................................. 9
12.
Make Final Tubing Connections
................................................................................................................ 9
13.
Install Icemaker Hookup (optional)
......................................................................................................... 10
14.
Install Filter Cartridges
........................................................................................................................... 10
15.
Start Up the System
............................................................................................................................... 10
16.
Installation Troubleshooting
.................................................................................................................... 11
17.
Maintenance
........................................................................................................................................... 12
18.
Parts List
................................................................................................................................................. 14
19.
Installation Diagrams (Figures 1-6)
......................................................................................................... 15
20.
Limited One Year Warranty
..................................................................................................................... 18
• Failure to follow instructions may void warranty.