6
ENGLISH
Cleaner Specifications
General Specifications
The general specifications for the cleaner are
as follows:
Control box
supply voltage
100-240 VAC, 50-60 Hz
Output voltage 30 V DC
Installed load
100 W max
When unpacking the cleaner and its
components:
•
Check cleaner and components for damage
during transport.
•
If there are any missing parts or damage,
contact Technical Support at 1-800-221-1750
Connect to Power
WARNING
•
Failure to comply with the following warnings
can result in permanent injury, electrocution
or drowning.
•
Prevent Electrical Shock
•
U.S.: Per NEC
®
requirements, keep the
control unit at least five (5) ft. (1.5 m) from
the edge of the pool. CANADA: Per CEC
requirements, keep the control unit at least
three (3)m (10 ft.) from the edge of the pool.
•
Only connect the control unit to a
receptacle protected by a ground fault
circuit interrupter (GFCI). Contact a certified
electrician if you cannot verify that the
receptacle is protected by a GFCI.
•
Do not use an extension cord to connect the
control unit.
•
Do not allow anyone to swim while the
cleaner is in the pool.
•
The control unit is not waterproof. In order to
prevent electrocution, never submerge the
control unit or leave exposed to inclement
weather.
1. Plug power supply into a GFCI outlet
(Ground Fault Circuit Interrupter)
(Figure 1). Power Supply must be 5 ft.
from the pool's edge.
Figure 1.
Plug into Power Supply
2. Straighten the floating cable. Lift the
flap on the power supply and plug in
the power cable (Figure 2).
Figure 2.
Connect the Power Cable
Summary of Contents for SSDP37 Series
Page 13: ...13 ENGLISH NOTES ...
Page 14: ...14 ENGLISH NOTES ...
Page 15: ...15 ENGLISH NOTES ...
Page 29: ...29 FRANÇAIS NOTES ...
Page 30: ...30 FRANÇAIS NOTES ...
Page 31: ...31 FRANÇAIS NOTES ...
Page 45: ...45 ESPAÑOL NOTAS ...
Page 46: ...46 ESPAÑOL NOTAS ...
Page 47: ...47 ESPAÑOL NOTAS ...