6
| AQM ELECTRIC TANKLESS WATER HEATERS
WWW.APTANKLESS.COM
TEMPERATURE INCREASE ABOVE AMBIENT WATER TEMPERATURE
4.
Temperature increase above ambient water temperature
Temp. rise above incoming water temp. (
°
F)
Temp. rise above incoming water temp. (
°
C)
GPM
l/m
Unit
Heating Capacity
0.32
0.42
0.48
0.53
0.69
0.85
1.06
1.14
1.2
1.6
1.8
2.0
2.6
3.2
4.0
4.3
AQM 2-1
1.8 kW @ 110–120 V
39
-
-
-
-
-
-
-
22
-
-
-
-
-
-
-
AQM 2.5-1
2.4 kW @ 110
–
120 V
-
39
34
33
24
-
-
-
-
22
19
17
13
-
-
-
AQM 3-1
3.0 kW @ 110–120 V
-
49
43
41
30
-
-
-
-
27
24
22
17
-
-
-
AQM 3.5-1
3.5 kW @ 110
–
120 V
-
57
50
45
35
-
-
-
-
31
28
25
19
-
-
-
AQM 4-2
3.5 kW @ 220–240 V
-
57
50
45
35
-
-
-
-
31
28
25
19
-
-
-
AQM 6-2
5.7 kW @ 220–240 V
-
-
-
-
-
46
37
34
-
-
-
-
-
25.5
20.4
19.0