Aqua One Ocellaris 400 Instructions Manual Download Page 7

7

13. Clean the impeller chamber using a double ended 

pipe brush.

14. Pull the rubber end cap off the shaft of the impeller 

and  run  water  through  the  hole  in  the  middle  of  the 

impeller.  Clean  any  debris  which  may  have  built  up 

on the shaft off, along with any slime build up on the 

impeller.

Rubber End Cap

Impeller

15. Put the impeller back together and ensure that it 

rotates freely on the shaft. Then reassemble the head 

unit, ensure there is no water on the power cord, plug 

the head unit in and turn on. Make certain the impeller 

is spinning. Turn it off. Reassemble the filter unit. Apply 

an aquarium safe lubricant to the O-ring on the head 

unit. This will provide a better water seal and make the 

removal of the head easier next time the filter has to be 

disassembled for maintenance. 

1. Check your inlet, outlet tubes and hoses. If residue 

has built up on the inside of them remove them from the 

aquarium. Take to the sink, run hot water through them 

to  loosen  the  slime.  Run  a  double  ended  pipe  brush 

through them, and flush again with hot water. This build 

up will reduce the flow rate of your filter considerably, 

so clean whenever it is possible.

20. Return the canister filter to your cabinet or stand 

and reattach the hoses.

21.  Refer  to  the  section  in  this  instruction  manual 

Starting You Filter for details on restarting the unit

Maintenance

1. Turn the canister filter off at the socket and unplug.

2.  Place  a  towel  or  a  shallow  container  under  the 

canister unit. This will prevent any water spilling onto 

your cabinet or stand and damaging it.

3.  Fill  a  bucket  with  water  from  your  aquarium  and 

take it to the sink or wherever you intend to clean your 

filter. Keep in mind cleaning your filter can be messy, 

cleaning is recommended outside or at a sink. Ensure 

the area is clean and free from soaps and detergents.

4. Open the canister. Release the 4 clips and remove 

the head unit, place it somewhere safe where it will not 

be trodden on or broken.

5.  Remove  the  sponge,  noodles  and  wool  cartridge 

from the canister body. 

6. Pour the water from the canister body out of the filter, 

ensuring none of the media is lost. Using the bucket of 

aquarium water, fill the canister enough that the media 

is  submerged.  Shake  the  canister  gently  to  rinse  the 

media. Empty the water from the filter. Repeat this until 

the water being emptied is clean.

7. Either replace or rinse the white wool cartridge using 

a high pressure hose. It should be replaced regularly 

or when it begins to deteriorate and can no longer be 

cleaned properly.

8. The sponge and noodles can also be rinsed in the 

bucket  of  aquarium  water  (refill  from  the  aquarium  if 

necessary).  The sponge will also require replacement 

eventually as over time it will clog and prevent water 

from traveling through easily.

9. Place the media back into the correct position in the 

canister body. 

10. The impeller should also be cleaned whenever the 

filter is disassembled. 

11. Turn the head unit over, remove the screws in the 

impeller cover and remove it.

Impeller cover

Screws

12.  Then  pull  the  impeller  cap  off  and  remove  the 

impeller.

Summary of Contents for Ocellaris 400

Page 1: ...Ocellaris 400 Instruction version 30 06 2014 www aquaone com au Inspiring Excellence in Fish Care 2 1 Marine Tropical Coldwater ...

Page 2: ...wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully ...

Page 3: ...the product have been found and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the n...

Page 4: ... 5 1 6 Recommended Filter Media Set Up Inlet Outlet Parts 1 Ceramic Noodles 2 Wool Cartridge 3 Sponge Black 35ppi Setup Parts 1 Hosetail 2 Inlet elbow 3 Extension pipe 4 Inlet strainer 5 Outlet Elbow 6 Spray bar ...

Page 5: ... of the filter unit You will need two pieces of hose Screw the collar on the taps all the way in clockwise 8 Now push one end of the hose over the hose tail and thread Push it on as far as possible Then turn the collar anti clockwise to lock in the hose Repeat for the other hose 9 Place the canister in the desired position and feed the hose through the cabinet or stand Assembling the inlet and out...

Page 6: ... up the water in the aquarium particularly if water has been siphoned from the aquarium to the filter Add water conditioner to water that is added Method 2 1 Temporarily detach the outlet from the tubing and create a siphon by sucking on the tube Once the siphon begins lower the outlet tube into a bucket 2 Wait until the canister is completely full of water You will know this when the water starts...

Page 7: ...container under the canister unit This will prevent any water spilling onto your cabinet or stand and damaging it 3 Fill a bucket with water from your aquarium and take it to the sink or wherever you intend to clean your filter Keep in mind cleaning your filter can be messy cleaning is recommended outside or at a sink Ensure the area is clean and free from soaps and detergents 4 Open the canister ...

Page 8: ...ilter will not start 1 As previous tips 2 Check the impeller and shaft are in good condition 3 Ensure the filter is plugged in Low water flow 1 As both previous tips 2 Clean or replace the filter media 3 Clean the inlet and outlet hoses 4 Clean all tubing Both water air coming from the outlet pipe 1 Leave for 3 5 minutes 2 Make sure that no air stone is operating near the intake strainer 3 Check a...

Page 9: ...9 ...

Page 10: ... of this product This marking indicates that this product should not be disposed with other household waste throughout the EU To prevent harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the produc...

Page 11: ... on the applicable Aqua One website refer below 2 3 Upon receipt and acceptance of the questionnaire Aqua One will forward by way of email a Certificate of Extended Guarantee to the purchaser 2 4 For more information on how we collect hold use and disclose personal information provided to us please refer to our Privacy Statement on the Aqua One websites or write to our Privacy Officer in your coun...

Page 12: ...12 Inspiring Excellence in Fish Care ...

Reviews: