background image

5

GB

Before First Use / Preparation

Read  and  follow  all  the  instructions,  even  if  you  feel 

you  are  familiar  with  the  product  and  find  a  place  to 

keep  the  instructions  handy  for  future  reference. 

Your  attention  is  drawn  particularly  to  the  sections 

concerning 

“IMPORTANT  SAFEGUARDS”

  and  the 

“GUARANTEE  CONDITIONS”

.  Please  ensure  you 

retain your original purchase receipt in the event that 

guarantee service is required.

Carefully unpack the product making sure you keep all 

the packing material until all the parts of the product have 

been found and the product has been assembled.

This  product  is  shipped  to  you  in  a  factory  sealed 

carton.  Should  the  product  malfunction  in  any  way 

or  if  the  unit  is  damaged  and  requires  replacement, 

contact the retailer where the product was purchased 

for inspection.

Aqua One Spare Parts

Replacement Parts & Filter Media

Use Aqua One Genuine Spare Parts Only. 

See your local Aqua One Dealer and look 

for  the  number  listed  below  for  the  spare 

part you require. Alternatively you will find 

these numbers on the  silver label located 

on the product.

Moray 360/480 Impeller  

 

10i

Moray 1300 Impeller    

 

12i

Moray 2300 Impeller    

 

14i

Moray 3600 Impeller    

 

17i-N

Moray 4900 Impeller    

 

18i-N

Moray 1300 Sponge    

 

12s

Moray 2300 Sponge    

 

13s

Moray 3600/4900 Sponge    

17s

10

I

Summary of Contents for Moray Series

Page 1: ...Moray Aquarium Pumps Inspiring Excellence in Fish Keeping www aquaone com au ...

Page 2: ...ulseur Spécifications Garantie Belangrijke voorzorgsmaatregelen Vóór eerste gebruik Voorbereiding Over Uw Pomp 360 480 Over Uw Pomp 1300 Over Uw Pomp 2300 3600 4900 Pomp Installeren 360 480 1300 Pomp Installeren 2300 3600 4900 Onderhoud Problemen Oplossen Toegang Tot Het Vleugelrad Specificaties Garantie Important Safeguards Before First Use Preparation Know Your Pump 360 480 Know Your Pump 1300 K...

Page 3: ... wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully...

Page 4: ...und and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Aqua One Spare Parts Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the numb...

Page 5: ...1 Motor 2 Venturi outlet 3 12mm joiner 4 Duckbill 5 Hang bracket 6 Rubber end cap 7 Impeller 8 Shaft 9 Venturi adjuster and airline 10 Impeller cover lock 11 Internal strainer 12 Uplift adapter 13 Strainer 6 1 2 7 8 3 4 5 9 10 11 12 13 ...

Page 6: ... Hang bracket 3 Rubber end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover lock 7 Internal strainer 8 Uplift adapter 9 Sponge 10 Strainer 11 Venturi outlet 12 Barbed 19mm hose tail 13 Venturi adjuster and airline 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 7: ...bber end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover 7 Impeller lock 8 Internal strainer 9 Sponge 10 Strainer 11 Barbed 25mm hose tail 3600 4900 12 Threaded reducer 3600 4900 13 Barbed 19mm hose tail 14 Inlet elbow 3600 4900 1 3 4 2 5 6 7 8 9 10 11 12 13 14 ...

Page 8: ...iner and slide the base plate out towards the impeller 2 Slide the hang mount into the groves at the back of the pump 3 Replace the strainer If being used They are also provided with multiple outlet options 1 Duckbill or multi directional outlet allows the water to be channelled a variety of different directions Good for providing water flow to static areas of the aquarium thus reducing waste buil...

Page 9: ...ability to pick up water from a lower point reducing the risk of the pump running dry NOTE it is always recommended that the pump be fully immersed in water to avoid the unit overheating If these pumps are being used in salt water they must be checked regularly for buildup of calcium and other deposits To maximise the life of your pump it is recommended to clean the pump casing and the impeller ev...

Page 10: ... could damage your pump 9 Ensure both rubber end caps are in the correct position If they do not come out when the impeller is removed one should be in the impeller chamber and the other in the impeller cover Failure to position them correctly will result in your pump being damaged 10 Do not force the unit back together as the ceramic shaft may break If it does not reassemble easily check the posi...

Page 11: ... Moray 4900 Maximum Flow Rate 4800L hr Maximum Head Height 3 6m Power Requirements 220 240V Power Consumption 100W Suitable Cold water Tropical Marine Disposal of used Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that the product must not be disposed of with no...

Page 12: ...ermines goods are being used in a manner contrary to the instructions specifications or this Guarantee Aqua One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to Guarantee 3 1 Goods claims where fault is due to but ...

Reviews: